A new engine-driven canal preparation system with electronic canal measuring capability

被引:41
作者
Kobayashi, C
Yoshioka, T
Suda, H
机构
[1] Department of Endodontics, Faculty of Dentistry, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, 113, 5-45, 1-chome, Yushima
关键词
D O I
10.1016/S0099-2399(97)80349-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A new cordless engine-driven root canal preparation system has been developed that electronically monitors the location of the file tip and the torque applied to the file during all instrumentation procedures, The Root ZX is mounted inside the handpiece to measure the canal length, The engine is driven with a rechargeable battery, and it works more than 40 minutes without a recharge. Nickel-titanium files are used for this preparation system, The file is rotated at 240 to 280 rpms, When the file tip reaches the apical constriction, the revolution of the file can be automatically reversed (Auto-apical-reverse mechanism). If there is too much torque, the rotation is automatically reversed (Auto-torque-reverse mechanism). These automatic functions promise a safer engine preparation of the canal with nickel-titanium files.
引用
收藏
页码:751 / 754
页数:4
相关论文
共 13 条
[1]   TORSIONAL AND STIFFNESS PROPERTIES OF NICKEL-TITANIUM K-FILES [J].
CAMPS, JJ ;
PERTOT, WJ .
INTERNATIONAL ENDODONTIC JOURNAL, 1995, 28 (05) :239-243
[2]  
Christie W H, 1993, J Can Dent Assoc, V59, P765
[3]   A COMPARISON OF CANAL PREPARATION WITH NICKEL-TITANIUM AND STAINLESS-STEEL INSTRUMENTS [J].
ESPOSITO, PT ;
CUNNINGHAM, CJ .
JOURNAL OF ENDODONTICS, 1995, 21 (04) :173-176
[4]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[5]   COMPARISON OF ROOT-CANAL PREPARATION USING DIFFERENT AUTOMATED DEVICES AND HAND INSTRUMENTATION [J].
HULSMANN, M ;
STRYGA, F .
JOURNAL OF ENDODONTICS, 1993, 19 (03) :141-145
[6]   Assessing apical deformation and transportation following the use of LightSpeed(TM) root-canal instruments [J].
Knowles, KI ;
Ibarrola, JL ;
Christiansen, RK .
INTERNATIONAL ENDODONTIC JOURNAL, 1996, 29 (02) :113-117
[7]   NEW ELECTRONIC CANAL MEASURING DEVICE BASED ON THE RATIO METHOD [J].
KOBAYASHI, C ;
SUDA, H .
JOURNAL OF ENDODONTICS, 1994, 20 (03) :111-114
[8]   A new ultrasonic canal preparation system with electronic monitoring of file tip position [J].
Kobayashi, C ;
Yoshioka, T ;
Suda, H .
JOURNAL OF ENDODONTICS, 1996, 22 (09) :489-492
[9]   A COMPARISON OF 4 INSTRUMENTATION TECHNIQUES ON APICAL CANAL TRANSPORTATION [J].
LUITEN, DJ ;
MORGAN, LA ;
BAUMGARTNER, JC ;
MARSHALL, JG .
JOURNAL OF ENDODONTICS, 1995, 21 (01) :26-32
[10]  
MISERENDINO LJ, 1994, PATHWAYS PULP, P388