A dc microplasma on a chip employed as an optical emission detector for gas chromatography

被引:142
作者
Eijkel, JCT
Stoeri, H
Manz, A [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Zeneca SmithKline Beecham Ctr Analyt Sci, London SW7 2AY, England
[2] Vienna Univ Technol, Inst Allgemeine Phys, A-1040 Vienna, Austria
关键词
D O I
10.1021/ac991380d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micromachined plasma chip is coupled to a conventional gas chromatograph to investigate its performance as an optical emission detector. The device employs a 180-nL plasma chamber in which an atmospheric pressure de glow discharge is generated in helium. Applied power is 9 mW (770 V, 12 mu A) and helium flow rate 320 nL s(-1). A number of carbon-containing compounds are detected in the column effluent by recording the emission at 519 nm. For hexane, the detector has a linear dynamic range of over two decades and a minimum detectability of 10(-12) g s(-1) (800 ppb). The detector signal shows a marked peak broadening and tailing when compared with the signal of a flame ionization detector. This is mainly attributed to dead volumes and chromatographic processes introduced by the connecting tubing and the chip glass channels. The device was operated for more than 24 h without a significant change in performance. Operation is stable and instrumental requirements are simple. Future use of the detector chip in conventional gas chromatography or as an integrated detector in on-chip gas chromatography is discussed.
引用
收藏
页码:2547 / 2552
页数:6
相关论文
共 20 条
[1]   DIRECT CURRENT DISCHARGE SPECTRAL EMISSION-TYPE DETECTOR [J].
BRAMAN, RS ;
DYNAKO, A .
ANALYTICAL CHEMISTRY, 1968, 40 (01) :95-&
[2]   ELECTROPHORETIC THERMAL THEORY .3. STEADY-STATE TEMPERATURE-GRADIENTS IN RECTANGULAR SECTION COLUMNS [J].
BROWN, JF ;
HINCKLEY, JON .
JOURNAL OF CHROMATOGRAPHY, 1975, 109 (02) :225-231
[3]   Potential of radio frequency glow discharge optical emission spectrometry for the analysis of gaseous samples [J].
Centineo, G ;
Fernandez, M ;
Pereiro, R ;
SanzMedel, A .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3702-3707
[4]   CHARACTERIZATION OF AN ANNULAR HELIUM INDUCTIVELY COUPLED PLASMA GENERATED IN A LOW-GAS-FLOW TORCH [J].
CHAN, SK ;
MONTASER, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (04) :591-597
[5]   ALTERNATING-CURRENT PLASMA DETECTOR FOR SELECTIVE MERCURY DETECTION IN GAS-CHROMATOGRAPHY [J].
COSTANZO, RB ;
BARRY, EF .
ANALYTICAL CHEMISTRY, 1988, 60 (08) :826-829
[6]   A molecular emission detector on a chip employing a direct current microplasma [J].
Eijkel, JCT ;
Stoeri, H ;
Manz, A .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2600-2606
[7]   An atmospheric pressure dc glow discharge on a microchip and its application as a molecular emission detector [J].
Eijkel, JCT ;
Stoeri, H ;
Manz, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (03) :297-300
[8]   A microwave-induced plasma based on microstrip technology and its use for the atomic emission spectrometric determination of mercury with the aid of the cold-vapor technique [J].
Engel, U ;
Bilgiç, AM ;
Haase, O ;
Voges, E ;
Broekaert, JAC .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :193-197
[9]  
ESTES SA, 1981, ANAL CHEM, V53, P1829, DOI 10.1021/ac00235a026
[10]   EQUATIONS FOR CALCULATION OF CHROMATOGRAPHIC FIGURES OF MERIT FOR IDEAL AND SKEWED PEAKS [J].
FOLEY, JP ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :730-737