Optimal location of a single distal interlocking screw in intramedullary nailing of distal third femoral shaft fractures

被引:39
作者
George, CJ [1 ]
Lindsey, RW [1 ]
Noble, PC [1 ]
Alexander, JW [1 ]
Kamaric, E [1 ]
机构
[1] Baylor Coll Med, Joseph Barnhart Dept Orthoped Surg, Houston, TX 77030 USA
关键词
femur; fracture fixation device; intramedullary nail; biomechanics; distal interlocking screw;
D O I
10.1097/00005131-199805000-00009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: This biomechanical study was done to determine the effect of the level of a single distal screw in a static intramedullary (IM) femoral nail on the stability of fixation of a fracture in the distal third of the femur. Design: Fifteen composite fiberglass femora were osteotomized transversely in the distal third of the femur. A Grosse-Kempf nail was implanted into the femurs, which were divided into three groups of five specimens. Single screw distal nail locking was varied distal to the osteotomy site for each group at 2.5, 5.0, and 7.5 centimeters, respectively. Intervention: All instrumented femurs were mounted on a servohydraulic testing machine and fitted with transducers to measure axial, rotational, and bending displacements. Specimens were cyclically loaded (one hertz) in simultaneous torsion (moment: +/-10 newton-meters) and axial compression (amplitude: 2,000 newtons) for 500 cycles with a 250-pound abductor force. Main Outcome Measurement: Data from Linear and rotational transducers were sampled at 100 hertz for five cycles before cycling, every 100 cycles of loading,and immediately after cycling. Custom computer software was developed to convert transducer signals into static and dynamic measurements of axial motion (in millimeters), rotation (in degrees), and angulation (in degrees). Results: Osteotomy site dynamic rotation increased significantly in specimens locked at 7.5 centimeters when compared with the 2.5-centimeter group. There was minimal difference between the stability of the 5.0-centimeter and 7.5-centimeter groups. There was no significant change in position at the fracture site before or after cyclic loading with respect to axial shortening, rotation, or bending. Both dynamic axial and angular displacements were also unaffected by screw position. Conclusion: The location of a single distal interlocking screw in static IM nail fixation of distal third femur fractures can significantly affect rotational stability but not axial or angular fixation.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 24 条
[1]
BANKSTON AB, 1992, CLIN ORTHOP RELAT R, P277
[2]
A COMPARISON OF THE BROOKER-WILLS AND RUSSELL-TAYLOR NAILS FOR TREATMENT OF PATIENTS WHO HAVE FRACTURES OF THE FEMORAL-SHAFT [J].
BLUMBERG, KD ;
FOSTER, WC ;
BLUMBERG, JF ;
ADELAAR, RS ;
DEBLOIS, ME ;
HUSSEY, RW ;
LOUGHRAN, TP ;
CARDEA, JA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (07) :1019-1024
[3]
BOHLER J, 1968, CLIN ORTHOP RELAT R, P51
[4]
INTRAMEDULLARY NAILING OF FEMORAL-SHAFT FRACTURES .2. FRACTURE-HEALING WITH STATIC INTERLOCKING FIXATION [J].
BRUMBACK, RJ ;
UWAGIEERO, S ;
LAKATOS, RP ;
POKA, A ;
BATHON, GH ;
BURGESS, AR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (10) :1453-1462
[5]
INTRAMEDULLARY NAILING OF FEMORAL-SHAFT FRACTURES .1. DECISION-MAKING ERRORS WITH INTERLOCKING FIXATION [J].
BRUMBACK, RJ ;
REILLY, JP ;
POKA, A ;
LAKATOS, RP ;
BATHON, GH ;
BURGESS, AR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (10) :1441-1452
[6]
BUCHOLZ RW, 1987, J BONE JOINT SURG AM, V69A, P1391
[7]
CLOSED INTRAMEDULLARY NAILING OF FEMUR [J].
CLAWSON, DK ;
SMITH, RF ;
HANSEN, ST .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (04) :681-&
[8]
IRRADIATION OF THE SURGEON DURING PINNING OF FEMORAL FRACTURES [J].
GIACHINO, AA ;
CHENG, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1980, 62 (02) :227-229
[9]
GROVER JS, 1972, 59 ANN M AM AC ORTH
[10]
THE USE OF ONE COMPARED WITH 2 DISTAL SCREWS IN THE TREATMENT OF FEMORAL-SHAFT FRACTURES WITH INTERLOCKING INTRAMEDULLARY NAILING - A CLINICAL AND BIOMECHANICAL ANALYSIS [J].
HAJEK, PD ;
BICKNELL, HR ;
BRONSON, WE ;
ALBRIGHT, JA ;
SAHA, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (04) :519-525