Randomized comparison of anatomical versus voltage guided ablation of the cavotricuspid isthmus for atrial flutter

被引:20
作者
Hall, B [1 ]
Veerareddy, S [1 ]
Cheung, P [1 ]
Good, E [1 ]
Lemola, K [1 ]
Han, J [1 ]
Kamala, T [1 ]
Chugh, A [1 ]
Pelosi, F [1 ]
Morady, F [1 ]
Oral, H [1 ]
机构
[1] Univ Michigan, Div Cardiol, Ann Arbor, MI USA
关键词
atrial flutter; catheter ablation; radiofrequency; voltage;
D O I
10.1016/j.hrthm.2004.01.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this prospective study was to compare radiofrequency catheter ablation of the cavotricuspid isthmus using a strictly anatomic approach to an approach guided by a bipolar voltage map to avoid high voltage zones in the cavotricuspid isthmus. BACKGROUND It is not clear whether local atrial electrogram amplitude influences the achievement of complete cavotricuspid isthmus block during radiofrequency catheter ablation for atrial flutter. METHODS Thirty-two patients with atrial flutter were randomized to cavotricuspid isthmus ablation using an anatomical approach (group I,16 patients) or guided by a bipolar voltage map (group II,16 patients). A 3-dimensional electroanatomic mapping system and an 8-mm-tip ablation catheter were used in all patients. With the anatomical approach, an ablation line was created in the cavotricuspid isthmus at a 6 o'clock position in the 45 degree left anterior oblique projection. During voltage-guided ablation, a high-density bipolar voltage map of the cavotricuspid isthmus was created, and then contiguous applications of radiofrequency energy were delivered to create an ablation line through the cavotricuspid isthmus sites with the lowest bipolar voltage. RESULTS Complete cavotricuspid isthmus conduction block was achieved in 100% of patients in each group. The mean maximum voltages along the line were 3.6 +/- 1.5 mV in group I, and 1.2 +/- 0.9 mV in group II (P < .01). Creating a high-density voltage map was associated with similar to 15-minute increase in the total procedure time (P = .2). During a mean follow-up of 177 +/- 40 days, there were no recurrences of atrial flutter in either group. There were no complications in either group. CONCLUSIONS When cavotricuspid isthmus ablation for atrial flutter is performed with an 8-mm-tip catheter, complete block can be achieved in all patients regardless of local voltage. Ablation of high voltage zones is not associated with a higher recurrence rate. Therefore, anatomic ablation without voltage mapping is the preferred initial approach for cavotricuspid isthmus ablation. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 9 条
[1]   Radiofrequency catheter ablation of common atrial flutter: Comparison of electrophysiologically guided focal ablation technique and linear ablation technique [J].
Chen, SA ;
Chiang, CE ;
Wu, TJ ;
Tai, CT ;
Lee, SH ;
Cheng, CC ;
Chiou, CW ;
Ueng, KC ;
Wen, ZC ;
Chang, MS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (04) :860-868
[2]   Electromagnetic versus fluoroscopic mapping of the inferior isthmus for ablation of typical atrial flutter -: A prospective randomized study [J].
Kottkamp, H ;
Hügl, B ;
Krauss, B ;
Wetzel, U ;
Fleck, A ;
Schuler, G ;
Hindricks, G .
CIRCULATION, 2000, 102 (17) :2082-2086
[3]   Atrial electrogram amplitude and efficacy of cavotricuspid isthmus ablation for atrial flutter [J].
Ozaydin, M ;
Tada, H ;
Chugh, A ;
Scharf, C ;
Lai, SWK ;
Pelosi, F ;
Knight, BP ;
Morady, F ;
Oral, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (09) :1859-1863
[4]   Radio frequency catheter ablation of atrial flutter - Further insights into the various types of isthmus block: Application to ablation during sinus rhythm [J].
Poty, H ;
Saoudi, N ;
Nair, M ;
Anselme, F ;
Letac, B .
CIRCULATION, 1996, 94 (12) :3204-3213
[5]   High-density mapping of activation through an incomplete isthmus ablation line [J].
Shah, D ;
Haïssaguerre, M ;
Jaïs, P ;
Takahashi, A ;
Hocini, M ;
Clémenty, J .
CIRCULATION, 1999, 99 (02) :211-215
[6]   Randomized comparison of anatomic and electrogram mapping approaches to ablation of typical atrial flutter [J].
Tada, H ;
Oral, H ;
Ozaydin, M ;
Chugh, A ;
Scharf, C ;
Hassan, S ;
Greenstein, R ;
Pelosi, F ;
Knight, BP ;
Strickberger, SA ;
Morady, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (07) :662-666
[7]   Double potentials along the ablation line as a guide to radiofrequency ablation of typical atrial flutter [J].
Tada, H ;
Oral, H ;
Sticherling, C ;
Chough, SP ;
Baker, RL ;
Wasmer, K ;
Pelosi, F ;
Knight, BP ;
Strickberger, SA ;
Morady, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) :750-755
[8]   Electrogram polarity and cavotricuspid isthmus block during ablation of typical atrial flutter [J].
Tada, H ;
Oral, H ;
Sticherling, C ;
Chough, SP ;
Baker, RL ;
Wasmer, K ;
Kim, MH ;
Pelosi, F ;
Michaud, GF ;
Knight, BP ;
Strickberger, SA ;
Morady, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (04) :393-399
[9]   Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter? [J].
Tsai, CF ;
Tai, CT ;
Yu, WC ;
Chen, YJ ;
Hsieh, MH ;
Chiang, CE ;
Ding, YA ;
Chang, MS ;
Chen, SA .
CIRCULATION, 1999, 100 (07) :768-771