On-line system for peptide mapping by capillary electrophoresis at sub-micromolar concentrations

被引:40
作者
Bonneil, E [1 ]
Waldron, KC [1 ]
机构
[1] Univ Montreal, Dept Chim, Montreal, PQ H3C 3J7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
preconcentration; solid-phase extraction; peptide mapping; capillary electrophoresis; protein digestion; trypsin microreactor; insulin chain B; cytochrome c; beta-casein;
D O I
10.1016/S0039-9140(00)00554-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Peptide mapping has been widely used for the identification of modified proteins involved in certain diseases. Despite the fact that capillary electrophoresis (CE) has been shown to be a powerful tool for the separation and detection of tryptic peptide fragments after protein digestion? this technique lacks sensitivity for mapping proteins isolated in very small quantities from biological samples. Consequently, it has been necessary to preconcentrate the protein before adding the proteolytic enzyme for digestion in solution. These experimental steps are quite long, labor intensive and require a lot of sample handling. In this paper, we describe an on-line system allowing digestion of the protein, followed by preconcentration, separation and detection of the tryptic fragments in 4 h. Up to an 800-fold preconcentration factor was achieved for cytochrome c, despite a loss of separation efficiency induced by the multiple-valve design of the system and dispersion of the 60-nl desorption plug. Moreover, our system showed good migration time reproducibility between peptide maps and could be reused for several samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:687 / 699
页数:13
相关论文
共 40 条
[1]   ANALYSIS OF DILUTE PEPTIDE SAMPLES BY CAPILLARY ZONE ELECTROPHORESIS [J].
AEBERSOLD, R ;
MORRISON, HD .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :79-88
[2]   TRYPSIN-MODIFIED FUSED-SILICA CAPILLARY MICROREACTOR FOR PEPTIDE-MAPPING BY CAPILLARY ZONE ELECTROPHORESIS [J].
AMANKWA, LN ;
KUHR, WG .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1610-1613
[3]  
BENSON LM, 1994, HRC-J HIGH RES CHROM, V17, P671
[4]   Characterization of a solid-phase extraction device for discontinuous on-line preconcentration in capillary electrophoresis-based peptide mapping [J].
Bonneil, E ;
Waldron, KC .
JOURNAL OF CHROMATOGRAPHY B, 1999, 736 (1-2) :273-287
[5]   Reproducibility of a solid-phase trypsin microreactor for peptide mapping by capillary electrophoresis [J].
Bonneil, E ;
Mercier, M ;
Waldron, KC .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :29-45
[6]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[7]   Z-SHAPED FLOW CELL FOR UV-DETECTION IN CAPILLARY ELECTROPHORESIS [J].
CHERVET, JP ;
VANSOEST, REJ ;
URSEM, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (02) :439-449
[8]   HIGH-SENSITIVITY PEPTIDE-MAPPING BY CAPILLARY ZONE ELECTROPHORESIS AND MICROCOLUMN LIQUID-CHROMATOGRAPHY, USING IMMOBILIZED TRYPSIN FOR PROTEIN DIGESTION [J].
COBB, KA ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1989, 61 (20) :2226-2231
[9]   Hydrophobic peptide mapping of clinically relevant heptahelical membrane proteins by capillary electrophoresis [J].
Dong, MQ ;
Oda, RP ;
Strausbauch, MA ;
Wettstein, PJ ;
Landers, JP ;
Miller, LJ .
ELECTROPHORESIS, 1997, 18 (10) :1767-1774
[10]   Identification of proteins by capillary electrophoresis tandem mass spectrometry - Evaluation of an on-line solid-phase extraction device [J].
Figeys, D ;
Ducret, A ;
Aebersold, R .
JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) :295-306