Flow-PRA® evaluation for antibody screening in patients awaiting kidney transplantation

被引:28
作者
Rebibou, JM
Chabod, J
Bittencourt, MC
Thevénin, C
Chalopin, JM
Hervé, P
Tiberghien, P
机构
[1] EFS Bourgogne Franche Comte, Lab Immunogenet, F-25020 Besancon, France
[2] CHU Besancon, Serv Nephrol & Tranpslantat, F-25030 Besancon, France
关键词
flow cytometric crossmatch; complement-dependent cytotoxicity crossmatch; antibody; low-level immunization; kidney transplantation;
D O I
10.1016/S0966-3274(00)00019-8
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Flow-PRA(R) is a flow cytometric method for both anti-HLA class I and class II antibody (Ab) detection. We evaluated this technique for Ab screening in patients awaiting kidney transplantation. After having established a rigorous threshold for positivity, a three-dilution difference in sensitivity between Flow-PRA(R) and complement-dependent cytotoxicity (CDC) persisted. The sensitivity of the method was satisfactory since all CDC-positive sera were also found to be positive with the Flow-PRA(R) method. Discrimination between anti-HLA class I and class II Abs was excellent. Furthermore, all sera responsible for a positive flow cytometry crossmatch (FCXM) and a negative CDC-crossmatch (CDC,XM) at the time of a putative transplant were found to be positive with Flow-PRA(R) beads. The specificity was excellent for anti-class I Ab detection since no false positive serum was found. On the other hand, the specificity was lower for anti-class II detection, since 8.3% (2/24) false positive results were detected among all the negative sera tested. Overall, our results suggested that Flow-PRA(R) should be of value for anti-HLA Ab screening prior to kidney transplantation. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:125 / 128
页数:4
相关论文
共 11 条
[1]   Impaired renal graft survival after a positive B-cell flow-cytometry crossmatch [J].
Bittencourt, MC ;
Rebibou, JM ;
Saint-Hillier, Y ;
Chabod, J ;
Dupont, I ;
Chalopin, JM ;
Herve, P ;
Tiberghien, P .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (08) :2059-2064
[2]   No advantage of flow cytometry crossmatch over complement-dependent cytotoxicity in immunologically well-documented renal allograft recipients [J].
Christiaans, MHL ;
Overhof, R ;
tenHaaft, A ;
Nieman, F ;
vanHooff, JP ;
vandenBergLoonen, EM .
TRANSPLANTATION, 1996, 62 (09) :1341-1347
[3]   RENAL RETRANSPLANTATION - THE ROLE OF RACE QUADRUPLE IMMUNOSUPPRESSION, AND THE FLOW-CYTOMETRY CROSS-MATCH [J].
GASTON, RS ;
SHROYER, TW ;
HUDSON, SL ;
DEIERHOI, MH ;
LASKOW, DA ;
BARBER, WH ;
JULIAN, BA ;
CURTIS, JJ ;
BARGER, BO ;
DIETHELM, AG .
TRANSPLANTATION, 1994, 57 (01) :47-54
[4]   Flow cytometry-detected IgG is not a contraindication to renal transplantation - IgM may be beneficial to outcome [J].
Kerman, RH ;
Susskind, B ;
Buyse, I ;
Pryzbylowski, P ;
Ruth, J ;
Warnell, S ;
Gruber, SA ;
Katz, S ;
Van Buren, CT ;
Kahan, BD .
TRANSPLANTATION, 1999, 68 (12) :1855-1858
[5]   IDENTIFICATION OF PATIENTS AT RISK FOR INFERIOR RENAL-ALLOGRAFT OUTCOME BY A STRONGLY POSITIVE B-CELL FLOW-CYTOMETRY CROSS-MATCH [J].
LAZDA, VA .
TRANSPLANTATION, 1994, 57 (06) :964-969
[6]   Simultaneous HLA class I and class II antibodies screening with flow cytometry [J].
Pei, R ;
Wang, G ;
Tarsitani, C ;
Rojo, S ;
Chen, T ;
Takemura, S ;
Liu, A ;
Lee, J .
HUMAN IMMUNOLOGY, 1998, 59 (05) :313-322
[7]  
SCORNIK JC, 1994, TRANSPLANTATION, V57, P621
[8]   Multicenter evaluation of the flow cytometry T-cell crossmatch - Results from the American Society of Histocompatibility and Immunogenetics-College of American Pathologists Proficiency Testing Program [J].
Scornik, JC ;
Bray, RA ;
Pollack, MS ;
Cook, DJ ;
Marrari, M ;
Duquesnoy, R ;
Langley, JW .
TRANSPLANTATION, 1997, 63 (10) :1440-1445
[9]   The use of magnetic beads coated with soluble HLA class I or class II proteins in antibody screening and for specificity determination of donor-reactive antibodies [J].
SumitranKaruppan, S ;
Moller, E .
TRANSPLANTATION, 1996, 61 (10) :1539-1545
[10]   RAPID DETECTION OF LOW-LEVELS OF DONOR SPECIFIC IGG BY FLOW-CYTOMETRY WITH SINGLE AND DUAL COLOR FLUORESCENCE IN RENAL-TRANSPLANTATION [J].
TALBOT, D ;
GIVAN, AL ;
SHENTON, BK ;
STRATTON, A ;
PROUD, G ;
TAYLOR, RMR .
JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 112 (02) :279-283