Noninvasive measurement of regional cerebral blood flow by near-infrared spectroscopy and indocyanine green

被引:149
作者
Kuebler, WM
Sckell, A
Habler, O
Kleen, M
Kuhnle, GEH
Welte, M
Messmer, K
Goetz, AE
机构
[1] Univ Munich, Klinikum Grosshadern, Inst Anesthesiol, D-81366 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Inst Surg Res, D-81366 Munich, Germany
关键词
cerebral blood flow; near-infrared spectroscopy; indocyanine green; radioactive microspheres; blood flow index;
D O I
10.1097/00004647-199804000-00013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Clinicians lack a practical method for measuring CBF rapidly, repeatedly, and noninvasively at the bedside. A new noninvasive technique for estimation of cerebral hemodynamics by use of near-infrared spectroscopy (NIRS) and an intravenously infused tracer dye is proposed. Kinetics of the infrared tracer indocyanine green were monitored on the intact skull in pigs. According to an algorithm derived from fluorescein flowmetry, a relative blood flow index (BFI) was calculated. Data obtained were compared with cerebral and galeal blood flow values assessed by radioactive microspheres under baseline conditions and during hemorrhagic shock and resuscitation. Blood flow index correlated significantly (r(s) = 0.814, P < 0.001) with cortical blood flow but not with galeal blood flow (r(s) = 0.258). However, limits of agreement between BFI and CBF are rather wide (+/- 38.2 +/- 6.4 mL 100 g(-1) min(-1)) and require further studies. Data presented demonstrate that detection of tracer kinetics in the cerebrovasculature by NIRS may serve as valuable tool for the noninvasive estimation of regional CBF. Indocyanine green dilution curves monitored noninvasively on the intact skull by NIRS reflect dye passage through the cerebral, not extracerebral, circulation.
引用
收藏
页码:445 / 456
页数:12
相关论文
共 73 条
[1]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[2]   SECONDARY INSULTS DURING INTRAHOSPITAL TRANSPORT OF HEAD-INJURED PATIENTS [J].
ANDREWS, PJD ;
PIPER, IR ;
DEARDEN, NM ;
MILLER, JD .
LANCET, 1990, 335 (8685) :327-330
[3]   THE THEORETICAL BASIS FOR THE DETERMINATION OF OPTICAL PATHLENGTHS IN TISSUE - TEMPORAL AND FREQUENCY-ANALYSIS [J].
ARRIDGE, SR ;
COPE, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (07) :1531-1560
[4]   INCREASED NUMBER OF MYOCARDIAL BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED MICROSPHERES [J].
BAER, RW ;
PAYNE, BD ;
VERRIER, ED ;
VLAHAKES, GJ ;
MOLODOWITCH, D ;
UHLIG, PN ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (03) :H418-H434
[5]   ADVERSE REACTIONS TO INDOCYANINE GREEN - A CASE-REPORT AND A REVIEW OF THE LITERATURE [J].
BENYA, R ;
QUINTANA, J ;
BRUNDAGE, B .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 17 (04) :231-233
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   MODEL FOR PHOTON MIGRATION IN TURBID BIOLOGICAL MEDIA [J].
BONNER, RF ;
NOSSAL, R ;
HAVLIN, S ;
WEISS, GH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (03) :423-432
[8]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[9]  
CARSKI TR, 1978, JAMA-J AM MED ASSOC, V240, P635
[10]   COMPARISON OF TIME-RESOLVED AND TIME-UNRESOLVED MEASUREMENTS OF DEOXYHEMOGLOBIN IN BRAIN [J].
CHANCE, B ;
LEIGH, JS ;
MIYAKE, H ;
SMITH, DS ;
NIOKA, S ;
GREENFELD, R ;
FINANDER, M ;
KAUFMANN, K ;
LEVY, W ;
YOUNG, M ;
COHEN, P ;
YOSHIOKA, H ;
BORETSKY, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (14) :4971-4975