Numerical calculation of the electroosmotic flow at the cross region in microfluidic chips

被引:38
作者
Jin, Y [1 ]
Luo, GA [1 ]
机构
[1] Tsing Hua Univ, Dept Chem, Beijing 100084, Peoples R China
关键词
cross region; electroosmotic flow; microfluidic chips; miniaturization; numerical calculation;
D O I
10.1002/elps.200390160
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A numerical study is presented for the electroosmotic flow (EOF) at the cross region in microfluidic chips. The distributions of the electric potential due to the electric double layer (EDL) and the external electric field are discussed and the calculation of the latter can give rough speculations on the flow tendencies in the channels during various operation modes. Simplification of the two-dimensional Navier-Stokes (N-S) equations is obtained by focusing on the solution of interior flows, and the numerical calculation results show good agreement with the experimental images. The sample leakage to the separation channel during the "float" sampling proved to be caused not only by the sample diffusion, but also by the weak extension of the sampling electric field. It is also verified that with suitable voltage configuration, the "pinch" sampling mode is better than the "float" mode in sample plug control.
引用
收藏
页码:1242 / 1252
页数:11
相关论文
共 28 条
[1]   Finite element simulation of an electroosmotic-driven flow division at a T-junction of microscale dimensions [J].
Bianchi, F ;
Ferrigno, A ;
Girault, HH .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :1987-1993
[2]  
BRIAN BH, 1999, ANAL CHEM, V71, P5137
[3]   ELECTROKINETIC FLOW IN ULTRAFINE CAPILLARY SLITS [J].
BURGREEN, D ;
NAKACHE, FR .
JOURNAL OF PHYSICAL CHEMISTRY, 1964, 68 (05) :1084-&
[4]   Conditions for similitude between the fluid velocity and electric field in electroosmotic flow [J].
Cummings, EB ;
Griffiths, SK ;
Nilson, RH ;
Paul, PH .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2526-2532
[5]   TIMESCALES OF TRANSIENT PROCESSES IN CAPILLARY ELECTROPHORESIS [J].
DOSE, EV ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) :263-275
[6]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[7]   Computer simulations of electrokinetic transport in microfabricated channel structures [J].
Ermakov, SV ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (21) :4494-4504
[8]  
Fu LM, 2002, ELECTROPHORESIS, V23, P602, DOI 10.1002/1522-2683(200202)23:4<602::AID-ELPS602>3.0.CO
[9]  
2-N
[10]   Band spreading in two-dimensional microchannel turns for electrokinetic species transport [J].
Griffiths, SK ;
Nilson, RH .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5473-5482