Reappraisal of single-sample and gamma camera methods for determination of the glomerular filtration rate with 99mTc-DTPA

被引:31
作者
Itoh, K
Tsushima, S
Tsukamoto, E
Tamaki, N
机构
[1] JR Sapporo Gen Hosp, Dept Radiol, Chuo Ku, Sapporo, Hokkaido 0600033, Japan
[2] JR Sapporo Gen Hosp, Dept Internal Med, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Sch Med, Dept Nucl Med, Sapporo, Hokkaido 060, Japan
关键词
glomerular filtration rate; radionuclide; Tc-99m-DTPA; plasma sample method; renography;
D O I
10.1007/BF02987852
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to assess the clinical validity of single-sample methods and gamma camera uptake methods with Tc-99m-DTPA for the estimation of the glomerular filtration rate (GFR). The study was performed in 50 patients with various degrees of renal function (29 males and 21 females; age 27-90 yrs; serum creatinine level 0.34-6.49 mg/dl). As a reference the "true" GFR (GFRt) was determined from plasma clearance by means of the two compartment model curve fitting 10 plasma samples. The GFRt of more than 30 ml/min in 46 patients was compared to the GFR which was estimated with 7 single-sample methods, two gamma camera uptake methods and 24-hour endogenous creatinine clearance (24hCcr). Close correlation was observed in all single-sample methods. The highest linear correlation was observed in the: Christensen and Groth's method rewritten by Watson for a 180-min plasma sample (r = 0.991, see = 5.84 ml/min). The smallest random error was observed in the Groth and Aasted's method for a 180-min plasma (r = 0.989, see = 4.31 ml/min/1.73 m(2)). Our method was lowest in % absolute difference analysis (mean = 4.10%). The gamma camera uptake methods correlated significantly with the GFRt (r = 0.746-0.774), but were less reliable than any of the single-sample methods (see = 15.41 ml/min-19.14 ml/min). The lowest correlation was observed in the 24hCcr (r = 0.698, see = 50.76 ml/min/1.73 m(2)). The singlesample method was more accurate than the gamma camera method, and the gamma camera method was more accurate than 24hCcr. The single-sample method should be recommended for the accurate determination of the GFR with Tc-99m-DTPA in a patient with mild to moderate renal dysfunction.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 30 条
[1]  
Blaufox MD, 1996, J NUCL MED, V37, P1883
[2]  
BOSCH JP, 1995, SEMIN NEPHROL, V15, P381
[3]   CURRENT STATUS ON ASSESSMENT AND MEASUREMENT OF GLOMERULAR-FILTRATION RATE [J].
BROCHNERMORTENSEN, J .
CLINICAL PHYSIOLOGY, 1985, 5 (01) :1-17
[4]  
BUBECK B, 1992, EUR J NUCL MED, V19, P511
[5]  
CHRISTENSEN AB, 1986, CLIN PHYSIOL, V6, P579
[6]   RADIONUCLIDE CLEARANCE TECHNIQUES [J].
COHEN, ML .
SEMINARS IN NUCLEAR MEDICINE, 1974, 4 (01) :23-38
[7]   SINGLE SAMPLE ESTIMATES OF RENAL CLEARANCES [J].
CONSTABLE, AR ;
HUSSEIN, MM ;
ALBRECHT, MP ;
THOMPSON, FD ;
PHILALITHIS, PE ;
JOEKES, AM .
BRITISH JOURNAL OF UROLOGY, 1979, 51 (02) :84-87
[8]  
Dakubu S, 1980, NUCL MED COMMUN, V1, P83
[9]   A formula to estimate the approximate surface area if height and weight be known [J].
Du Bois, D ;
Du Bois, EF .
ARCHIVES OF INTERNAL MEDICINE, 1916, 17 (06) :863-871