Torus factor - The relationship between radiofrequency field and radial position in toroid cavity probes

被引:10
作者
Woelk, K [1 ]
机构
[1] Univ Bonn, Inst Phys & Theoret Chem, D-53115 Bonn, Germany
关键词
torus factor; toroid cavity detector; rotating-frame imaging; radiofrequency field gradient; Brent algorithm;
D O I
10.1006/jmre.2000.2144
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Toroid detectors are resonators for high-pressure in situ NMR spectroscopy or one-dimensional rotating-frame imaging. One of their unique qualities is a mathematically well-defined nonuniform radiofrequency field confined to the inside of the detector. A single parameter (i.e., the torus factor) is sufficient to describe the relationship between this radiofrequency field and the radial distance from the center axis of the torus. Because accurate determination of the torus factor is essential to optimize toroid cavity NMR experiments or conduct toroid cavity imaging, a fast numerical algorithm for accurate, precise, and convenient determination of torus factors from pulse width-dependent signal intensities is introduced. In addition, the new algorithm provides for 99% confidence intervals around the refined torus factors. A computer program in which the optimization progress is visualized during the torus factor refinement is presented. Upon completion of the program, the best-fit simulated data and the residuals between best fit and experimental data are provided. (C) 2000 Academic Press.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 16 条
[1]   SPATIAL LABELING BY A RADIOFREQUENCY FIELD GRADIENT - DANTE-Z PROFILE, PROBED BY ONE-DIMENSIONAL NUTATION IMAGING [J].
BOUDOT, D ;
CANET, D ;
BRONDEAU, J .
JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (02) :385-394
[2]  
Brent R.P., 1973, ALGORITHMS MINIMIZAT
[3]  
HOULT DI, 1979, J MAGN RESON, V33, P183, DOI 10.1016/0022-2364(79)90202-6
[4]   SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT [J].
HOULT, DI ;
RICHARDS, RE .
JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) :71-85
[5]  
LEHNHOF E, 1997, THESIS U BONN GERMAN
[6]   AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS [J].
MARQUARDT, DW .
JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02) :431-441
[7]  
METZ K R, 1988, Magnetic Resonance Imaging, V6, P53
[8]   RAPID ROTATING-FRAME IMAGING USING AN RF PULSE-TRAIN (RIPT) [J].
METZ, KR ;
BOEHMER, JP ;
BOWERS, JL ;
MOORE, JR .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (02) :152-161
[9]  
*NMR, 1997, TABL OTH US INF, P2
[10]  
Press W. H., 1992, NUMERICAL METHODS C, P354