Proteomics profiling of urine with surface enhanced laser desorption/ionization time of flight mass spectrometry

被引:22
作者
Roelofsen, Han [1 ]
Alvarez-Llamas, Gloria [1 ]
Schepers, Marianne [1 ]
Landman, Karloes [1 ]
Vonk, Roel J. [1 ]
机构
[1] Univ Groningen, Med Ctr, Ctr Med Biom, Groningen, Netherlands
来源
PROTEOME SCIENCE | 2007年 / 5卷
关键词
RENAL-ALLOGRAFT REJECTION; NEPHROTIC SYNDROME; BIOMARKERS; DISCOVERY; PROTEINS;
D O I
10.1186/1477-5956-5-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Urine consists of a complex mixture of peptides and proteins and therefore is an interesting source of biomarkers. Because of its high throughput capacity SELDI-TOF-MS is a proteomics technology frequently used in biomarker studies. We compared the performance of seven SELDI protein chip types for profiling of urine using standard chip protocols. Results: Performance was assessed by determining the number of detectable peaks and spot to spot variation for the seven array types and two different matrices: SPA and CHCA. A urine sample taken from one healthy volunteer was applied in eight-fold for each chip type/matrix combination. Data were analyzed for total number of detected peaks (S/N > 5). Spot to spot variation was determined by calculating the average CV of peak intensities. In addition, an inventory was made of detectable peaks with each chip and matrix type. Also the redundancy in peaks detected with the different chip/matrix combinations was determined. A total of 425 peaks (136 non-redundant peaks) could be detected when combining the data from the seven chip types and the two matrices. Most peaks were detected with the CM10 chip with CHCA (57 peaks). The Q10 with CHCA (51 peaks), SEND (48 peaks) and CM10 with SPA (48 peaks) also performed well. The CM10 chip with CHCA also has the best reproducibility with an average CV for peak intensity of 13%. Conclusion: The combination of SEND, CM10 with CHCA, CM10 with SPA, IMAC-Cu with SPA and H50 with CHCA provides the optimal information from the urine sample with good reproducibility. With this combination a total of 217 peaks (71 non-redundant peaks) can be detected with CV's ranging from 13 to 26%, depending on the chip and matrix type. Overall, CM10 with CHCA is the best performing chip type.
引用
收藏
页数:9
相关论文
共 25 条
[1]   Characterization of renal allograft rejection by urinary proteomic analysis [J].
Clarke, W ;
Silverman, BC ;
Zhang, Z ;
Chan, DW ;
Klein, AS ;
Molmenti, EP .
ANNALS OF SURGERY, 2003, 237 (05) :660-664
[2]  
Dare TO, 2002, ELECTROPHORESIS, V23, P3241, DOI 10.1002/1522-2683(200209)23:18<3241::AID-ELPS3241>3.0.CO
[3]  
2-D
[4]  
Davis MT, 2001, PROTEOMICS, V1, P108, DOI 10.1002/1615-9861(200101)1:1<108::AID-PROT108>3.0.CO
[5]  
2-5
[6]  
Fung ET, 2002, BIOTECHNIQUES, P34
[7]  
HONG H, 2005, BMC BIOINFORMATICS, V6, P5
[8]   Urine proteomic profiling of pediatric nephrotic syndrome [J].
Khurana, Mona ;
Traum, Avram Z. ;
Aivado, Manuel ;
Wells, Meghan P. ;
Guerrero, Manuel ;
Grall, Franck ;
Libermann, Towia A. ;
Schachter, Asher D. .
PEDIATRIC NEPHROLOGY, 2006, 21 (09) :1257-1265
[9]  
Merchant M, 2000, ELECTROPHORESIS, V21, P1164, DOI 10.1002/(SICI)1522-2683(20000401)21:6<1164::AID-ELPS1164>3.0.CO
[10]  
2-0