8.0-Tesla human MR system: Temperature changes associated with radiofrequency-induced heating of a head phantom

被引:38
作者
Kangarlu, A
Shellock, FG
Chakeres, DW
机构
[1] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
[2] Univ So Calif, Inst Magnet Resonance Safety Educ & Res, Keck Sch Med, Los Angeles, CA USA
关键词
high magnetic field; magnetic resonance imaging; radio frequency heating; MRI safety; SAR;
D O I
10.1002/jmri.10236
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate if the heat induced in biological tissues by typical radio frequency (RF) energy associated with an 8.0-Tesla magnetic resonance (MR) system causes excessive temperature changes. Materials and Methods: Fluoroptic thermometry was used to measure temperatures in multiple positions in a head phantom made of ground turkey breast. A series of experiments were conducted with measurements obtained at RF power levels ranging from a specific absorption rate (SAR) of up to 4.0 W/kg for 10 minutes. Results: The highest temperature increases were up to 0.7degreesC. An inhomogeneous heating pattern was observed. In general, the deep regions within the phantom registered higher temperature increases compared to the peripheral sites. Conclusion: The expectation of an inhomogeneous RF distribution in ultra high field systems (> 4 T) was confirmed. At a frequency of 340 MHz and in-tissue RF wave length of about 10 cm, the RF inhomogeneity was measured to create higher temperatures in deeper regions of a human head phantom compared to peripheral tissues. Our results agree with the computational electromagnetic calculations for such frequencies. Importantly, these experiments indicated that there were no regions of heating that exceeded the current FDA guidelines.
引用
收藏
页码:220 / 226
页数:7
相关论文
共 36 条
[1]   EFFICIENT DECOUPLER COIL DESIGN WHICH REDUCES HEATING IN CONDUCTIVE SAMPLES IN SUPERCONDUCTING SPECTROMETERS [J].
ALDERMAN, DW ;
GRANT, DM .
JOURNAL OF MAGNETIC RESONANCE, 1979, 36 (03) :447-451
[3]   PROTON-DECOUPLED, OVERHAUSER-ENHANCED, SPATIALLY LOCALIZED C-13 SPECTROSCOPY IN HUMANS [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ROEMER, PB ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) :348-363
[4]   High signal-to-noise flash imaging at 8 Tesla [J].
Burgess, RE ;
Yu, Y ;
Abduljalil, AM ;
Kangarlu, A ;
Robitaille, PML .
MAGNETIC RESONANCE IMAGING, 1999, 17 (08) :1099-1103
[5]   Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil [J].
Collins, CM ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :684-691
[6]  
DUCK FA, 1993, PHYSICAL PROPERTIES, P346
[7]  
Gandhi OP, 1999, MAGN RESON MED, V41, P816, DOI 10.1002/(SICI)1522-2594(199904)41:4<816::AID-MRM22>3.0.CO
[8]  
2-5
[9]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[10]  
Hand JW, 2000, J MAGN RESON IMAGING, V12, P68, DOI 10.1002/1522-2586(200007)12:1<68::AID-JMRI7>3.0.CO