Intercomparison of boron isotope and concentration measurements.: Part II:: Evaluation of results

被引:152
作者
Gonfiantini, R
Tonarini, S
Gröning, M
Adorni-Braccesi, A
Al-Ammar, AS
Astner, M
Bächler, S
Barnes, RM
Bassett, RL
Cocherie, A
Deyhle, A
Dini, A
Ferrara, G
Gaillardet, J
Grimm, J
Guerrot, C
Krähenbühl, U
Layne, G
Lemarchand, D
Meixner, A
Northington, DJ
Pennisi, M
Reitznerová, E
Rodushkin, I
Sugiura, N
Surberg, R
Tonn, S
Wiedenbeck, M
Wunderli, S
Xiao, YK
Zack, T
机构
[1] CNR, Ist Geosci & Georisorse, Area Ric, I-56124 Pisa, Italy
[2] IAEA, Div Phys & Chem Sci, Vienna, Austria
[3] Univ Massachusetts, Dept Chem, Amherst, MA 01003 USA
[4] Univ Bern, Dept Chem & Biochem, Bern, Switzerland
[5] Geochem Technol Corp, Wheat Ridge, CO USA
[6] Bur Rech Geol & Minieres, F-45060 Orleans, France
[7] GEOMAR, Kiel, Germany
[8] Univ Paris 06, Inst Phys Globe, Paris, France
[9] Woods Hole Oceanog Inst, Woods Hole, MA 02543 USA
[10] Geoforschungszentrum Potsdam, D-14473 Potsdam, Germany
[11] W Coast Analyt Serv, Santa Fe Springs, CA USA
[12] Lulea Tekniska Univ, SGAB, Lulea, Sweden
[13] Univ Tokyo, Dept Earth & Planetary Sci, Tokyo, Japan
[14] Eidgenoss Mat & Forsch, St Gallen, Switzerland
[15] Chinese Acad Sci, Qinghai Inst Salt Lakes, Xining, Qinghai, Peoples R China
[16] Mem Univ Newfoundland, Dept Earth Sci, St John, NF, Canada
来源
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS | 2003年 / 27卷 / 01期
关键词
boron isotopes; boron concentration; reference materials; intercomparison of measurements;
D O I
10.1111/j.1751-908X.2003.tb00711.x
中图分类号
P [天文学、地球科学];
学科分类号
07 [理学];
摘要
The Istituto di Geoscienze e Georisorse (IGG), on behalf and with the support of the International Atomic Energy Agency (IAEA), prepared eight geological materials (three natural waters and five rocks and minerals), intended for a blind interlaboratory comparison of measurements of boron isotopic composition and concentration. The materials were distributed to twenty seven laboratories - virtually all those performing geochemical boron isotope analyses in the world which agreed to participate in the intercomparison exercise. Only fifteen laboratories, however, ultimately submitted the isotopic and/or concentration results they obtained on the intercomparison materials. The results demonstrate that interlaboratory reproducibility is not well reflected by the precision values reported by the individual laboratories and this observation holds true for both boron concentration and isotopic composition. The reasons for the discrepancies include fractionations due to the chemical matrix of materials, relative shift of the zero position on the 51113 scale and a lack of well characterized materials for calibrating absolute boron content measurements. The intercomparison materials are now available at the IAEA (solid materials) and IGG (waters) for future distribution.
引用
收藏
页码:41 / 57
页数:17
相关论文
共 29 条
[1]
BORON ISOTOPE ANALYSIS - A REVIEW [J].
AGGARWAL, JK ;
PALMER, MR .
ANALYST, 1995, 120 (05) :1301-1307
[2]
[Anonymous], 4032012 WST
[3]
Boron isotopic analysis of natural fresh and saline waters by negative thermal ionization mass spectrometry [J].
Barth, S .
CHEMICAL GEOLOGY, 1997, 143 (3-4) :255-261
[4]
Catanzaro E.J., 1970, SPECIAL PUBLICATION, V216-17
[5]
Analytical procedures for the measurement of boron isotope compositions by ion microprobe in meteorites and mantle rocks [J].
Chaussidon, M ;
Robert, F ;
Mangin, D ;
Hanon, P ;
Rose, EF .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1997, 21 (01) :7-17
[6]
Coplen T. B., 2002, 014222 US DEP INT US
[7]
Boron determination in twenty one silicate rock reference materials by isotope dilution ICP-MS [J].
D'Orazio, M .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1999, 23 (01) :21-29
[8]
De Bievre P, 1997, ACCREDIT QUAL ASSUR, V2, P270
[9]
Do interlaboratory comparisons provide traceability? [J].
De Bièvre, P .
ACCREDITATION AND QUALITY ASSURANCE, 1999, 4 (08) :342-346
[10]
Improvements of boron isotope analysis by positive thermal ionization mass spectrometry using static multicollection of Cs2BO2+ ions [J].
Deyhle, A .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 206 (1-2) :79-89