Biocompatibility and performance in vitro of a hemostatic gelatin sponge

被引:55
作者
Cenni, E [1 ]
Ciapetti, G
Stea, S
Corradini, A
Carozzi, F
机构
[1] Ist Ortoped Rizzoli, Dipartimento Putti, Bologna, Italy
[2] Mascia Brunelli SPA, Milan, Italy
关键词
hemostatic sponge; gelatin; cytotoxicity; genotoxicity; platelet;
D O I
10.1163/156856200743959
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The biocompatibility of a hemostatic gelatin sponge (Cutanplast Standard) was evaluated in vitro. Cytotoxicity was assessed by neutral red uptake and amido black staining tests; genotoxicity was assayed using the Ames test, Sister Chromatides Exchanges (SCE) and chromosomal aberrations. The ability of the hemostatic gelatin sponge to induce platelet adhesion and release reaction was also determined. The undiluted extract of the test material was found to be cytotoxic, but cell viability was not affected by 1:2 and 1:10 diluted extract. The same extract was found to be non-genotoxic using the three assays for genotoxicity. A significant decrease of platelet number, as well as a significant release of platelet factor 4 was found to be caused by the solid material. In conclusion, Cutanplast Standard is neither cytotoxic nor genotoxic, while inducing platelet adhesion and release reaction when challenged with blood.
引用
收藏
页码:685 / 699
页数:15
相关论文
共 36 条
[1]   CARCINOGENS ARE MUTAGENS - SIMPLE TEST SYSTEM COMBINING LIVER HOMOGENATES FOR ACTIVATION AND BACTERIA FOR DETECTION [J].
AMES, BN ;
DURSTON, WE ;
YAMASAKI, E ;
LEE, FD .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1973, 70 (08) :2281-2285
[2]   METHODS FOR DETECTING CARCINOGENS AND MUTAGENS WITH SALMONELLA-MAMMALIAN-MICROSOME MUTAGENICITY TEST [J].
AMES, BN ;
MCCANN, J ;
YAMASAKI, E .
MUTATION RESEARCH, 1975, 31 (06) :347-363
[3]   TISSUE REACTION TO SUBCUTANEOUS IMPLANTATION OF A COLLAGEN SPONGE - A HISTOLOGICAL, ULTRASTRUCTURAL, AND IMMUNOLOGICAL STUDY [J].
ANSELME, K ;
BACQUES, C ;
CHARRIERE, G ;
HARTMANN, DJ ;
HERBAGE, D ;
GARRONE, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (06) :689-703
[4]   DIFFERENTIAL EXPRESSION OF UPA IN AN AGGRESSIVE (DU-145) AND A NONAGGRESSIVE (1013L) HUMAN PROSTATE-CANCER XENOGRAFT [J].
BILLSTROM, A ;
LECANDER, I ;
DAGNAESHANSEN, F ;
DAHLLOF, B ;
STENRAM, U ;
HARTLEYASP, B .
PROSTATE, 1995, 26 (02) :94-104
[5]   UTILIZATION OF THE PLATELET-RELEASE REACTION IN THE BLOOD COMPATIBILITY ASSESSMENT OF POLYMERS [J].
BOWRY, SK ;
COURTNEY, JM ;
PRENTICE, CRM ;
DOUGLAS, JT .
BIOMATERIALS, 1984, 5 (05) :289-292
[6]  
CENNI E, 1991, POLYMERS AND BIOMATERIALS, P407
[7]  
Cenni E, 1997, J BIOMED MATER RES, V36, P289, DOI 10.1002/(SICI)1097-4636(19970905)36:3<289::AID-JBM3>3.0.CO
[8]  
2-A
[9]   Transcatheter oily chemoembolization of the inferior phrenic artery in hepatocellular carcinoma: The safety and potential therapeutic role [J].
Chung, JW ;
Park, JH ;
Han, JK ;
Choi, BI ;
Kim, TK ;
Han, MC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (03) :495-500
[10]   Application of a combination of neutral red and amido black staining for rapid, reliable cytotoxicity testing of biomaterials [J].
Ciapetti, G ;
Granchi, D ;
Verri, E ;
Savarino, L ;
Cavedagna, D ;
Pizzoferrato, A .
BIOMATERIALS, 1996, 17 (13) :1259-1264