Heme protein-gluten films: voltammetric studies and their electrocatalytic properties

被引:73
作者
Liu, HY [1 ]
Hu, NF [1 ]
机构
[1] Beijing Normal Univ, Dept Chem, Beijing 100875, Peoples R China
基金
中国国家自然科学基金;
关键词
direct electrochemistry; electrocatalysis; hemoglobin; myoglobin; horseradish peroxidase; gluten;
D O I
10.1016/S0003-2670(03)00071-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct electrochemistry and electrocatalysis of heme proteins, such as hemoglobin (Hb), myoglobin (Mb), and horseradish peroxidase (HRP), incorporated in gluten biopolymer films cast on pyrolytic graphite (PG) electrodes, were studied by voltammetry and amperometry. All the three protein-gluten films exhibited a pair of well-defined, quasi-reversible cyclic voltammetric peaks at about -0.28 V versus saturated calomel electrode (SCE) in pH 5.5 buffers, respectively, characteristic of the heme Fe(III)/Fe(II) redox couples, indicating enhanced electron transfer between the proteins and PG electrodes in a gluten film environment. The protein-gluten hydrogel films showed excellent stability. Positions of Soret absorption band of protein-gluten films suggested that the heme proteins kept their secondary structure similar to their native state in the films in the medium pH range. The heme proteins in gluten films were act as a biologic catalyst to catalyze reduction of oxygen or hydrogen peroxide. The voltammetric or amperometric responses of H2O2 at the protein-gluten film electrodes could be used to determine the concentration of H2O2 in solution. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 49 条
[1]   HETEROGENEOUS AND HOMOGENEOUS ELECTRON TRANSFERS TO AROMATIC HALIDES - ELECTROCHEMICAL REDOX CATALYSIS STUDY IN THE HALOBENZENE AND HALOPYRIDINE SERIES [J].
ANDRIEUX, CP ;
BLOCMAN, C ;
DUMASBOUCHIAT, JM ;
SAVEANT, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1979, 101 (13) :3431-3441
[2]  
ANDRIEUX CP, 1980, J ELECTROANAL CHEM, V19, P113
[3]   Reactions of complex metalloproteins studied by protein-film voltammetry [J].
Armstrong, FA ;
Heering, HA ;
Hirst, J .
CHEMICAL SOCIETY REVIEWS, 1997, 26 (03) :169-179
[4]  
BELLELLI A, 1990, J BIOL CHEM, V265, P18898
[5]  
BOND AM, 1980, MODERN POLAROGRAPHIC, P27
[6]   A bioelectrode for penicillin detection based on gluten-membrane-entrapped microbial cells [J].
Chao, HP ;
Lee, WC .
BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2000, 32 (32) :9-14
[7]  
Chaplin MF., 1990, ENZYME TECHNOLOGY
[8]   Facilitated electron transfer from an electrode to horseradish peroxidase in a biomembrane-like surfactant film [J].
Chen, XH ;
Peng, XS ;
Kong, JL ;
Deng, JQ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 480 (1-2) :26-33
[9]   Ordered electrochemically active films of hemoglobin, didodecyldimethylammonium ions, and clay [J].
Chen, XL ;
Hu, NF ;
Zeng, YH ;
Rusling, JF ;
Yang, J .
LANGMUIR, 1999, 15 (20) :7022-7030
[10]   Formulation of a biocontrol agent by entrapping biomass of Trichoderma viride in gluten matrix [J].
Cho, CF ;
Lee, WC .
JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 1999, 87 (06) :822-824