Dysphotopsia in phakic and pseudophakic patients: Incidence and relation to intraocular lens type

被引:105
作者
Tester, R [1 ]
Pace, NL [1 ]
Samore, M [1 ]
Olson, RJ [1 ]
机构
[1] Univ Utah, Hlth Sci Ctr, Salt Lake City, UT USA
关键词
D O I
10.1016/S0886-3350(00)00427-2
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose: To determine the relationship between various intraocular lens (IOL) types and the incidence of unwanted light images. Setting: The Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: A telephone questionnaire was administered to 302 postoperative patients who had received 1 of 6 commonly used IOLs between January and September 1998. Patients were included only if they had uneventful cataract surgery, no additional ocular pathology, and a postoperative best corrected visual acuity of 20/25 or better, A control group of 50 patients with the diagnosis of presbyopia only also participated in the questionnaire. Patients reported on incidence of glare, light sensitivity, and unwanted images. The data were analyzed for statistically significant relationships between incidence of photopsias and IOL type. Results: The AcrySof 5.5 mm, AcrySof 6.0 mm, and SI-40 groups reported significantly more unwanted images than the control group (P = .0014). The 2 AcrySof groups also reported a greater incidence of light to the side causing a central flash, and the SI-40 group, a higher incidence of glare. The control group was more likely to experience symptoms of glare than any pseudophakic group. Overall, a mean of 49% of patients reported some light-related phenomenon postoperatively. The majority in all groups reported being satisfied with their eyesight despite the light-related problems. Conclusions: A significant number of pseudophakic patients reported symptoms of dysphotopsia. Patients who received an acrylic IOL with flattened edges were at increased risk of experiencing images associated with edge reflections. The SI-40 lens group, although less than the AcrySof groups, reported a higher incidence of glare than the non-AcrySof groups; however, it also had the highest number of patients still driving at night. The phakic population commonly experienced glare reported as more severe than several of the IOL groups. (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:810 / 816
页数:7
相关论文
共 12 条
[1]
VISUAL DISTURBANCES ASSOCIATED WITH OVAL-OPTIC POLY(METHYL METHACRYLATE) AND ROUND-OPTIC SILICONE INTRAOCULAR LENSES [J].
ANDERSON, CJ ;
STURM, RJ ;
SHAPIRO, MB ;
BALLEW, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (03) :295-298
[2]
VISUAL ABERRATIONS CAUSED BY OPTIC COMPONENTS OF POSTERIOR CHAMBER INTRAOCULAR LENSES [J].
APPLE, DJ ;
LICHTENSTEIN, SB ;
HEERLEIN, K ;
LETCHINGER, SL ;
PARK, RB ;
BREMS, RN ;
PIEST, KL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1987, 13 (04) :431-435
[3]
UNWANTED OPTICAL-IMAGES WITH NARROW PROFILE INTRAOCULAR LENSES COMPARED WITH CONVENTIONAL INTRAOCULAR LENSES [J].
ARMSTRONG, TA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (05) :578-581
[5]
Analysis of edge glare phenomena in intraocular lens edge designs [J].
Holladay, JT ;
Lang, A ;
Portney, V .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (06) :748-752
[8]
UNDESIRED LIGHT IMAGES ASSOCIATED WITH OVOID INTRAOCULAR LENSES [J].
MASKET, S ;
GERAGHTY, E ;
CRANDALL, AS ;
DAVISON, JA ;
JOHNSON, SH ;
KOCH, DD ;
LANE, SS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (06) :690-694
[9]
MASKET S, 1998, J CATARACT REFR SURG, V24, P1554
[10]
MASKET S, 1997, J CATARACT REFR SURG, V23, P979