Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve

被引:87
作者
Lurie, KG
Mulligan, KA
McKnite, S
Detloff, B
Lindstrom, P
Lindner, KH
机构
[1] Univ Minnesota, Ctr Hlth, Cardiac Arrhythmia Ctr, Minneapolis, MN 55409 USA
[2] Univ Minnesota, Div Cardiovasc, Minneapolis, MN 55409 USA
[3] Univ Ulm, Dept Anesthesiol & Crit Care Med, Ulm, Germany
关键词
active compression-decompression CPR; cardiac arrest; cardiopulmonary resuscitation; heart; impedance threshold valve; ventricular fibrillation;
D O I
10.1378/chest.113.4.1084
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: This study was designed to assess whether intermittent impedance of inspiratory gas exchange improves the efficiency of standard cardiopulmonary resuscitation (CPR). Background: Standard CPR relies on the natural elastic recoil of the chest to transiently decrease intrathoracic pressures and thereby promote venous blood return to the heart. To further enhance the negative intrathoracic pressures during the "relaxation" phase of CPR, we tested the hypothesis that intermittent impedance to inspiratory gases during standard CPR increases coronary perfusion pressures and vital organ perfusion. Methods: CPR was performed with a pneumatically driven automated device in a porcine model of ventricular fibrillation. Eight pigs were randomized to initially receive standard CPR alone, while seven pigs initially received standard CPR plus intermittent impedance to inspiratory gas exchange with a threshold valve set to -40 cm H2O. The compression:ventilation ratio was 5:1 and the compression rate was 80/min. At 7-min intervals the impedance threshold valve (ITV) was either added or removed from the ventilation circuit such that during the 28 min of CPR, each animal received two 7-min periods of CPR with the ITV and two 7-min periods without the valve. Results: Vital organ blood flow was significantly higher during CPR performed with the ITV than during CPR performed without the valve. Total left ventricular blood flow (mean+/-SEM) (mL/min/g) was 0.32+/-0.04 vs 0.23+/-0.03 without the ITV (p<0.05). Cerebral blood flow (mL/min/g) was 20% higher with the ITV (+ITV, 0.23+/-0.02; -ITV, 0.19+/-0.02; p<0.05). Each time the ITV was removed, there was a statistically significant decrease in the vital organ blood flow and coronary perfusion pressure. Conclusions: Intermittent impedance to inspiratory now of respiratory gases during standard CPR significantly improves CPR efficiency during ventricular fibrillation. These studies underscore the importance of lowering intrathoracic pressures during the relaxation phase of CPR.
引用
收藏
页码:1084 / 1090
页数:7
相关论文
共 7 条
[1]   ACTIVE COMPRESSION-DECOMPRESSION CPR IMPROVES VITAL ORGAN PERFUSION IN A DOG-MODEL OF VENTRICULAR-FIBRILLATION [J].
CHANG, MW ;
COFFEEN, P ;
LURIE, KG ;
SHULTZ, J ;
BACHE, RJ ;
WHITE, CW .
CHEST, 1994, 106 (04) :1250-1259
[2]   ACTIVE COMPRESSION-DECOMPRESSION - A NEW METHOD OF CARDIOPULMONARY-RESUSCITATION [J].
COHEN, TJ ;
TUCKER, KJ ;
LURIE, KG ;
REDBERG, RF ;
DUTTON, JP ;
DWYER, KA ;
SCHWAB, TM ;
CHIN, MC ;
GELB, AM ;
SCHEINMAN, MM ;
SCHILLER, NB ;
CALLAHAM, ML .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (21) :2916-2923
[3]  
GULY UM, 1995, BRIT HEART J, V73, P372
[4]   EFFECTS OF ACTIVE COMPRESSION-DECOMPRESSION RESUSCITATION ON MYOCARDIAL AND CEREBRAL BLOOD-FLOW IN PIGS [J].
LINDNER, KH ;
PFENNINGER, EG ;
LURIE, KG ;
SCHURMANN, W ;
LINDNER, IM ;
AHNEFELD, FW .
CIRCULATION, 1993, 88 (03) :1254-1263
[5]  
LINDNER KH, 1996, BRIT HEART J, V75, P145
[6]   IMPROVING ACTIVE COMPRESSION-DECOMPRESSION CARDIOPULMONARY-RESUSCITATION WITH AN INSPIRATORY IMPEDANCE VALVE [J].
LURIE, KG ;
COFFEEN, P ;
SHULTZ, J ;
MCKNITE, S ;
DETLOFF, B ;
MULLIGAN, K .
CIRCULATION, 1995, 91 (06) :1629-1632
[7]   ACTIVE COMPRESSION-DECOMPRESSION CPR - A PROGRESS REPORT [J].
LURIE, KG .
RESUSCITATION, 1994, 28 (02) :115-122