Detection of glucose at 2 fM concentration

被引:43
作者
Mano, N [1 ]
Heller, A
机构
[1] Univ Texas, Dept Chem Engn, Austin, TX 78712 USA
[2] Univ Texas, Texas Mat Inst, Austin, TX 78712 USA
关键词
D O I
10.1021/ac0486746
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the amperometric detection of glucose at 2 fM concentration in a physiological buffer solution at 1 atm 0(2) pressure. The sensitive assay is based on the close to absolute electroreductive stripping Of O-2 from the solution near the glucose electrooxidizing anode. The glucose was detected by its electrooxidation on a stationary glassy carbon disk surrounded by an also stationary platinum ring. The disk was coated with a film of glucose oxidase (GOx), electrically "wired" with PVP-[Os(N,N'-dimethyl-2,2'-biimidazole)(3)](2+3+) (polymer I), having a redox potential of -0.19 V versus Ag/AgCl. The ring was coated with bilirubin oxidase (BOD) wired with PAA-PVI[Os(4,4'-dichloro-2,2'-bipyridine)(2)Cl](+/2+) (polymer II), having a redox potential of +0.36 V versus Ag/AgCI. The ring-disk electrode was held facing up, and a 30-muL drop was placed on it for the assay, with the ring poised at -0.3V/AgAgCl and the disk poised at - 0.1 V/Ag/AgCl. Even though the atmosphere over the drop was O-2 at 1 atm pressure, the wired BOD disk scavenged the O-2 so effectively that the glucose-reduced FADH(2) of GOx was not oxidized by O-2, the natural cosubstrate of the enzyme.
引用
收藏
页码:729 / 732
页数:4
相关论文
共 18 条
[1]   Supramolecular architectures of electrostatic self-assembled glucose oxidase enzyme electrodes [J].
Calvo, EJ ;
Wolosiuk, A .
CHEMPHYSCHEM, 2004, 5 (02) :235-239
[2]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[3]  
F Allen J Bard L.R., 2001, Electrochemical Methods: Fundamentals and Applications
[4]   ELECTRICAL WIRING OF REDOX ENZYMES [J].
HELLER, A .
ACCOUNTS OF CHEMICAL RESEARCH, 1990, 23 (05) :128-134
[5]   ELECTRICAL CONNECTION OF ENZYME REDOX CENTERS TO ELECTRODES [J].
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (09) :3579-3587
[6]   GLUCOSE-OXIDASE IMMOBILIZED BENZOQUINONE CARBON PASTE ELECTRODE AS A GLUCOSE SENSOR [J].
IKEDA, T ;
HAMADA, H ;
MIKI, K ;
SENDA, M .
AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1985, 49 (02) :541-543
[7]  
Ikeda T., 1985, ANAL SCI, V1, P455
[8]   Oxygen is electroreduced to water on a "wired" enzyme electrode at a lesser overpotential than on platinum [J].
Mano, N ;
Fernandez, JL ;
Kim, Y ;
Shin, W ;
Bard, AJ ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (50) :15290-15291
[9]   An oxygen cathode operating in a physiological solution [J].
Mano, N ;
Kim, HH ;
Zhang, YC ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (22) :6480-6486
[10]   On the relationship between the characteristics of bilirubin oxidases and O2 cathodes based on their "wiring" [J].
Mano, N ;
Kim, HH ;
Heller, A .
JOURNAL OF PHYSICAL CHEMISTRY B, 2002, 106 (34) :8842-8848