Preliminary results of the new 6F TrapEase inferior vena cava filter

被引:28
作者
Schutzer, R [1 ]
Ascher, E [1 ]
Hingorani, A [1 ]
Jacob, T [1 ]
Kallakuri, S [1 ]
机构
[1] Maimonides Hosp, Dept Surg, Div Vasc Surg, Brooklyn, NY 11219 USA
关键词
D O I
10.1007/s10016-001-0328-9
中图分类号
R61 [外科手术学];
学科分类号
摘要
The TrapEase filter is a permanent, symmetric nitinol filter that can be deployed through a low-profile sheath. Although the TrapEase is enjoying an increasing market share of inferior vena cava (IVC) filters, there are still limited clinical follow-up data on its use. This study is a retrospective review of 189 consecutive infrarenal TrapEase filters placed at our institution. The study included 80 men and 109 women, with an average age of 73 years (24-102). The most common indication for filter placement was a contraindication to warfarin. In total, 13% of the patients were treated with warfarin. The filter was successfully deployed in all cases, via the right femoral vein in 57% of the patients, via the left femoral vein in 32%, and via the right internal jugular vein in 11%. Follow-up studies were performed as clinically indicated. During the investigation, there were three cases of IVC thrombosis (1.5%) and one case of retroperitoneal hemorrhage potentially caused by filter placement. Two of the thrombosis cases resulted in serious sequelae. This study also represents the first report of a symptomatic pulmonary embolism (PE) after TrapEase filter placement. While this investigation does demonstrate a low overall complication rate of this new device, it raises the concern of an increase in IVC thrombosis rate.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 19 条
[1]  
ALPERT J, 1976, JAMA-J AM MED ASSOC, V36, P1477
[2]  
BERNSTEIN MJ, 1986, JAMA-J AM MED ASSOC, V256, P744
[3]  
BROWSE NL, 1974, LANCET, V1, P258
[4]   TrapEase inferior vena cava filter placed via the basilic arm vein: A new antecubital access [J].
Davison, BD ;
Grassi, CJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (01) :107-109
[5]   PERCUTANEOUS KIMRAY-GREENFIELD FILTER PLACEMENT BY FEMORAL VEIN PUNCTURE [J].
DENNY, DF ;
CRONAN, JJ ;
DORFMAN, GS ;
ESPLIN, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (04) :827-829
[6]  
*FDA, FDAS MAN US FAC DEV
[7]  
Grassi C J, 1992, J Vasc Interv Radiol, V3, P535, DOI 10.1016/S1051-0443(92)72008-9
[8]  
GREENFIELD LJ, 1973, SURGERY, V73, P599
[9]   Recurrent thromboembolism in patients with vena cava filters [J].
Greenfield, LJ ;
Proctor, MC .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (03) :510-514
[10]   THE SIMON NITINOL INFERIOR VENA-CAVA FILTER - PRELIMINARY EXPERIENCE IN THE UK [J].
HAWKINS, SP ;
ALKUTOUBI, A .