Atomic vector gradiometer system using cesium vapor cells for magnetocardiography: Perspective on practical application

被引:19
作者
Kim, Kiwoong [1 ]
Lee, Won-Kyu
Kim, In-Seon
Moon, Han Seb
机构
[1] Korea Res Inst Stand & Sci, Biosignal Res Lab, Taejon 305340, South Korea
[2] Korea Res Inst Stand & Sci, Length Time Metrol Grp, Taejon 305340, South Korea
[3] Pusan Natl Univ, Dept Phys, Pusan 609735, South Korea
关键词
atomic magnetometer; magnetocardiography (MCG); myocardial infarction; optical pumping magnetometer;
D O I
10.1109/TIM.2007.890610
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed an optical pumping magnetometer system for magnetocardiography (MCG). The basic system requirements for measuring MCG are as follows: a 5-mu T weak bias field in a magnetically shielded room, a 20-mm cell for spatial resolution, and a 30-Hz bandwidth for heart signals. In order to reduce the environmental magnetic noise, a double-cell gradiometer configuration has been adopted. The measured noise level was similar to 10 pT/root Hz. By switching current flows through a symmetrical three-axis rectangular Helmholtz coil set, the system is designed to measure three vector components of the magnetic field gradient. We show that this configuration reduces the error in current dipole localization with respect to the usual normal component detection by computer simulation of confidence-region estimation. Based on the simulation, we suggest that the system is applicable for diagnosing myocardial infarction on the anterior wall of a human heart in coronary artery disease.
引用
收藏
页码:458 / 462
页数:5
相关论文
共 14 条
[1]   A laser-pumped magnetometer for the mapping of human cardiomagnetic fields [J].
Bison, G ;
Wynands, R ;
Weis, A .
APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (03) :325-328
[2]   PRINCIPLES OF OPERATION OF THE RUBIDIUM VAPOR MAGNETOMETER [J].
BLOOM, AL .
APPLIED OPTICS, 1962, 1 (01) :61-68
[3]   RELAXATION OF OPTICALLY PUMPED RB ATOMS ON PARAFFIN-COATED WALLS [J].
BOUCHIAT, MA ;
BROSSEL, J .
PHYSICAL REVIEW, 1966, 147 (01) :41-&
[4]   MAGNETOCARDIOGRAMS TAKEN INSIDE A SHIELDED ROOM WITH A SUPERCONDUCTING POINT-CONTACT MAGNETOMETER [J].
COHEN, D ;
EDELSACK, EA ;
ZIMMERMAN, JE .
APPLIED PHYSICS LETTERS, 1970, 16 (07) :278-+
[5]  
Fenici R., 2003, INT J BIOELECTROMAGN, V5, P80
[6]   Confidence limits of dipole source reconstruction results [J].
Fuchs, M ;
Wagner, M ;
Kastner, J .
CLINICAL NEUROPHYSIOLOGY, 2004, 115 (06) :1442-1451
[7]   OPTICAL-PUMPING [J].
HAPPER, W .
REVIEWS OF MODERN PHYSICS, 1972, 44 (02) :169-&
[8]  
Kim K., 2004, NEUROL CLIN NEUROPHY, V60, P1
[9]   A microwave frequency reference based on VCSEL-driven dark line resonances in Cs vapor [J].
Kitching, J ;
Knappe, S ;
Vukicevic, N ;
Hollberg, L ;
Wynands, R ;
Weidmann, W .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (06) :1313-1317
[10]   A subfemtotesla multichannel atomic magnetometer [J].
Kominis, IK ;
Kornack, TW ;
Allred, JC ;
Romalis, MV .
NATURE, 2003, 422 (6932) :596-599