A general microcantilever surface modification method using a multilayer for biospecific recognition

被引:19
作者
Yan, XD
Lvov, Y
Ji, HF [1 ]
Singh, A
Thundat, T
机构
[1] Louisiana Tech Univ, Inst Micromfg, Ruston, LA 71272 USA
[2] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
[3] Oak Ridge Natl Lab, Div Life Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.1039/b209944f
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
The key to microcantilever surface modification technology is to selectively modify one side of a microcantilever surface with molecular recognition layers. In this paper, we report a general microcantilever modification method using a multilayer film.
引用
收藏
页码:460 / 462
页数:3
相关论文
共 19 条
[1]   MOISTURE ABSORPTION CHARACTERISTICS OF ORGANOSILOXANE SELF-ASSEMBLED MONOLAYERS [J].
ANGST, DL ;
SIMMONS, GW .
LANGMUIR, 1991, 7 (10) :2236-2242
[2]   A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout [J].
Battiston, FM ;
Ramseyer, JP ;
Lang, HP ;
Baller, MK ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Güntherodt, HJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) :122-131
[3]   Surface stress in the self-assembly of alkanethiols on gold probed by a force microscopy technique [J].
Berger, R ;
Delamarche, E ;
Lang, HP ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Guntherodt, HJ .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 66 (Suppl 1) :S55-S59
[4]   Fuzzy nanoassemblies: Toward layered polymeric multicomposites [J].
Decher, G .
SCIENCE, 1997, 277 (5330) :1232-1237
[5]   Factors controlling the growth of polyelectrolyte multilayers [J].
Dubas, ST ;
Schlenoff, JB .
MACROMOLECULES, 1999, 32 (24) :8153-8160
[6]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[7]   Acoustic wave microsensor arrays for vapor sensing [J].
Grate, JW .
CHEMICAL REVIEWS, 2000, 100 (07) :2627-2647
[8]   Cantilever-based optical deflection assay for discrimination of DNA single-nucleotide mismatches [J].
Hansen, KM ;
Ji, HF ;
Wu, GH ;
Datar, R ;
Cote, R ;
Majumdar, A ;
Thundat, T .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1567-1571
[9]   Multicomponent analysis and prediction with a cantilever array based gas sensor [J].
Kim, BH ;
Prins, FE ;
Kern, DP ;
Raible, S ;
Weimar, U .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :12-18
[10]   An artificial nose based on a micromechanical cantilever array [J].
Lang, HP ;
Baller, MK ;
Berger, R ;
Gerber, C ;
Gimzewski, JK ;
Battiston, FM ;
Fornaro, P ;
Ramseyer, JP ;
Meyer, E ;
Güntherodt, HJ .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :59-65