Development of a new standard laboratory protocol for estimating the field attenuation of hearing protection devices. Part III. The validity of using subject-fit data

被引:50
作者
Berger, EH [1 ]
Franks, JR
Behar, A
Casali, JG
Dixon-Ernst, C
Kieper, RW
Merry, CJ
Mozo, BT
Nixon, CW
Ohlin, D
Royster, JD
Royster, LH
机构
[1] EAR Aearo Co, Indianapolis, IN 46268 USA
[2] NIOSH, Cincinnati, OH 45226 USA
[3] Behar Noise Control, Scarborough, ON M1M 2X8, Canada
[4] Virginia Polytech Inst & State Univ, Blacksburg, VA 24061 USA
[5] ALCOA, Pittsburgh, PA 15219 USA
[6] USA, Aeromed Res Lab, Ft Rucker, AL 36330 USA
[7] Syst Res Labs Inc, Wright Patterson AFB, OH 45433 USA
[8] USA, Ctr Hlth Promot & Prevent Med, Aberdeen Proving Ground, MD 21010 USA
[9] Environm Noise Consultants Inc, Raleigh, NC 27622 USA
[10] N Carolina State Univ, Raleigh, NC 27695 USA
关键词
D O I
10.1121/1.423236
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The mandate of ASA Working Group S12/WG11 has been to develop "laboratory and/or field procedure(s) that yield useful estimates of field performance" of hearing protection devices (HPDs). A real-ear attenuation at threshold procedure was selected, devised, tested via an, interlaboratory study, and incorporated into a draft standard that was approved in 1997 [J. D. Royster et al., "Development of a new standard laboratory protocol for estimating the field attenuation of hearing protection devices. Part I. Research of Working Group 11, Accredited Standards Committee S12, Noise," J. Acoust. Soc. Am. 99, 1506-1526 (1996); ANSI S12.6-1997, "American National Standard Methods for Measuring Real-Ear Attenuation of Hearing Protectors" (American National Standards Institute, New York, 1997)]. The real-world estimation procedure utilizes a subject-fit methodology with Listeners who are audiometrically proficient, but inexperienced in the use of HPDs. A key factor in the decision to utilize the subject-fit method was an evaluation of the representativeness of the laboratory data vis-a-vis attenuation values achieved by workers in practice, Twenty-two field studies were reviewed to develop a data base for comparison purposes, Results indicated that laboratory subject-fit attenuation values were typically equivalent to or greater than the field attenuation values, and yielded a better estimate of those values than did experimenter-fit or experimenter-supervised fit types of results. Recent data which are discussed in the paper, but which were not available at the time of the original analyses, confirm the findings. (C) 1998 Acoustical Society of America. [S0001-4966(98)03001-X].
引用
收藏
页码:665 / 672
页数:8
相关论文
共 37 条
[1]  
AEL SM, 1982, PERSONAL HEARING PRO, P315
[2]  
*ANSI, 1984, S1261984 ANSI AM NAT
[3]  
*ANSI, 1974, S3191974 ANSI AM NAT
[4]  
*ANSI, 1997, S1261997 ANSI AM NAT
[5]   FIELD-EVALUATION OF HEARING PROTECTORS [J].
BEHAR, A .
NOISE CONTROL ENGINEERING JOURNAL, 1985, 24 (01) :13-18
[6]  
Berger E. H., 1988, Sound and Vibration, V22, P26
[7]  
Berger E.H., 1989, P 1989 IND HEAR CONS, P7
[8]  
Berger E.H., 1996, SPECTRUM S1, V13, P29
[9]  
Berger EH, 1996, SCIENTIFIC BASIS OF NOISE-INDUCED HEARING LOSS, P361
[10]  
BERGER EH, 1991, 9130HP EAR