Does low individual operator coronary interventional procedural volume correlate with worse institutional procedural outcome?

被引:36
作者
Klein, LW [1 ]
Schaer, GL [1 ]
Calvin, JE [1 ]
Palvas, B [1 ]
Allen, J [1 ]
Loew, J [1 ]
Uretz, E [1 ]
Parrillo, JE [1 ]
机构
[1] RUSH HEART INST,CHICAGO,IL
关键词
D O I
10.1016/S0735-1097(97)00272-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To assess the relation between individual operator coronary interventional volume and incidence of complications, the in-hospital outcome at a single, moderate volume urban academic center was prospectively collected over a 3-year period. Background. A minimum of 75 coronary interventions/operator per year may be required in the future to obtain formal certification. However, few data exist regarding individual operator volumes and procedural outcome. Methods. Between January 1993 and December 1995, 1,389 consecutive procedures were performed or supervised by nine geographic full-time operators: 171 (12.3%) utilized various devices, and 350 (25.2%) involved multivessel coronary intervention. Left ventricular ejection fraction was 59 +/- 15% (mean +/- SD), and there were 1.7 +/- 0.7 vessels diseased (with greater than or equal to 70% stenosis). Clinical indications included stable angina in 22.5% of cases, unstable angina in 31.9%, acute myocardial infarction (MI) in 2.9%, post MI in 20.6%, shock or acute heart failure in 3.0% and restenosis in 19.1%. In the last consecutive 857 lesions in 655 cases, 20.7% type A, 55.5% type B and 23.8% type C lesions were categorized before coronary intervention. Results. Average yearly operator volume ranged from 26 to 83 cases (mean 51 +/- 26). Each operator has performed a total of 590 +/- 268 coronary interventions, with 10.0 +/- 4.3 years of coronary interventional experience. The mean angioplasty volume rating for the nine operators,vas 180 +/- 37 (>170 considered adequate). The in hospital major complication rate was 1.4% (95% confidence interval 0.7% to 1.893%) for all coronary interventions, including death in 3 patients, bypass surgery in 13, arrhythmia in 3 and Q wave MI in 2. To ascertain how these outcomes compared with standard measures of coronary interventional outcome, four previously published registries were reanalyzed in a similar manner. The rate of complications in the present study was found to be significantly lower than that of the 1992-1993 Society for Cardiac Angiography and Intervention registry (1.9%, n = 19,594, p < 0.05 [excludes ventricular arrhythmias]), the 1994 American College of Cardiology database (3.9%, n = 38,963, p = 0.001), the Mid-America Heart Institute outcome in 1988 (2.3%, n = 5,413, p = 0.02) and the 1985-1986 National Heart, Lung, and Blood Institute Registry (7.2%, n = 1,801, p = 0.001). Odds ratios and 95% confidence intervals showed the outcome in the current study to be at least comparable to the standard registries. Conclusions. Despite individual operator volumes below those currently being considered for credentialing, the overall institutional outcome was excellent in a diverse and complex patient population. (C) 1997 by the American College of Cardiology.
引用
收藏
页码:870 / 877
页数:8
相关论文
共 23 条
[1]  
*ACC NAT DAT LIB, 1994, PREL TAB ANG VOL
[2]  
CONTI CR, 1995, CLIN CARDIOL, V18, P689
[3]   PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY IN 1985-1986 AND 1977-1981 - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE REGISTRY [J].
DETRE, K ;
HOLUBKOV, R ;
KELSEY, S ;
COWLEY, M ;
KENT, K ;
WILLIAMS, D ;
MYLER, R ;
FAXON, D ;
HOLMES, D ;
BOURASSA, M ;
BLOCK, P ;
GOSSELIN, A ;
BENTIVOGLIO, L ;
LEATHERMAN, L ;
DORROS, G ;
KING, S ;
GALICHIA, J ;
ALBASSAM, M ;
LEON, M ;
ROBERTSON, T ;
PASSAMANI, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (05) :265-270
[4]   Analysis and comparison of operator-specific outcomes in interventional cardiology - From a multicenter database of 4860 quality-controlled procedures [J].
Ellis, SG ;
Omoigui, N ;
Bittl, JA ;
Lincoff, M ;
Wolfe, MW ;
Howell, G ;
Topol, EJ .
CIRCULATION, 1996, 93 (03) :431-439
[5]  
HANNAN EL, 1997, JAMA-J AM MED ASSOC, V279, P892
[6]   PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - VIEW OF A SINGLE RELATIVELY HIGH-FREQUENCY OPERATOR [J].
HARTZLER, GO .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (10) :869-872
[7]   COMPARISON OF COMPLICATIONS DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY FROM 1977 TO 1981 AND FROM 1985 TO 1986 - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY REGISTRY [J].
HOLMES, DR ;
HOLUBKOV, R ;
VLIETSTRA, RE ;
KELSEY, SF ;
REEDER, GS ;
DORROS, G ;
WILLIAMS, DO ;
COWLEY, MJ ;
FAXON, DP ;
KENT, KM ;
BENTIVOGLIO, LG ;
DETRE, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (05) :1149-1155
[8]   RESULTS OF PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY BY MULTIPLE RELATIVELY LOW-FREQUENCY OPERATORS [J].
JACOB, AS ;
PICHARD, AD ;
OHNMACHT, SD ;
LINDSAY, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (10) :713-716
[9]   THE RELATION BETWEEN THE VOLUME OF CORONARY ANGIOPLASTY PROCEDURES AT HOSPITALS TREATING MEDICARE BENEFICIARIES AND SHORT-TERM MORTALITY [J].
JOLLIS, JG ;
PETERSON, ED ;
DELONG, ER ;
MARK, DB ;
COLLINS, SR ;
MUHLBAIER, LH ;
PRYOR, DB .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (24) :1625-1629
[10]   DEVELOPMENT AND VALIDATION OF A SIMPLIFIED PREDICTIVE INDEX FOR MAJOR COMPLICATIONS IN CONTEMPORARY PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY PRACTICE [J].
KIMMEL, SE ;
BERLIN, JA ;
STROM, BL ;
LASKEY, WK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (04) :931-938