Design and control of an upper limb rehabilitation support device for disabled people using a pneumatic cylinder

被引:16
作者
Kirihara, Koichi [1 ]
Saga, Norihiko [2 ]
Saito, Naoki [1 ]
机构
[1] Akita Prefectural Univ, Grad Sch Syst Sci & Technol, Yurihonjo, Japan
[2] Kwansei Gakuin Univ, Dept Human Syst Interact, Sanda, Japan
来源
INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION | 2010年 / 37卷 / 04期
关键词
Rehabilitation; Limbs; Robotics; Musculoskeletal system; Japan; TORQUE; ROBOT;
D O I
10.1108/01439911011044813
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose - The purpose of this paper is to describe the development of a device to support rehabilitation of a patient's upper limb motion. Design/methodology/approach - The device has five degrees of freedom by virtue of its link mechanism. It consists of Joints 1-5. Apparatus for use in so-called welfare applications, such as this device, must be safe, flexible, and lightweight. A pneumatic cylinder, arranged and integrated with the device, was used to operate it. The device has two rehabilitation modes corresponding to different rehabilitation contents. The first mode is the muscular recovery and movable region expansion mode (Mode A). The second mode is a practical function recovery mode (Mode B). A compliance control and a position control system are applied for those modes. Findings - By arranging the pneumatic cylinder optimally, results show that the device has compact and wide operating range and compliance-control performance for Mode A. Position-control performance for Mode B was verified experimentally. Moreover, the paper evaluates the effectiveness of the device and its control system through electromyography, which confirms that the developed device can support a patient's rehabilitation training. Originality/value - The device has a simple link mechanism and an attached pneumatic cylinder, thereby constituting a lightweight and compact mechanism. The device has two rehabilitation modes corresponding to different rehabilitation contents. Using the device, a patient can conduct muscular power recovery training, movable region expansion training, and upper limb practical function recovery training.
引用
收藏
页码:354 / 363
页数:10
相关论文
共 23 条
  • [1] Bien Z, 2003, IEEE ASME INT C ADV, P902
  • [2] BRUCE TV, 2001, CURRENT OPINION NEUR, V14, P745
  • [3] *CAB OFF JAP, 2008, ANN REP AG SOC
  • [4] RELATIONSHIP BETWEEN TORQUE AND EMG ACTIVITY OF A KNEE EXTENSOR MUSCLE DURING ISOKINETIC CONCENTRIC AND ECCENTRIC ACTIONS
    GHORI, GMU
    DONNE, B
    LUCKWILL, RG
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1995, 5 (02) : 109 - 115
  • [5] Torque control of a rehabilitation teaching robot using magneto-rheological fluid clutches
    Hakogi, H
    Ohaba, M
    Kuramochi, N
    Yano, H
    [J]. JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2005, 48 (03) : 501 - 507
  • [6] Robot-assisted reaching exercise promotes arm movement recovery in chronic hemiparetic stroke: a randomized controlled pilot study
    Kahn, Leonard E.
    Zygman, Michele L.
    Rymer, W. Zev
    Reinkensmeyer, David J.
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2006, 3 (1)
  • [7] Kiguchi K, 2003, IEEE ASME INT C ADV, P1228
  • [8] Koyanagi K, 2003, IEEE ASME INT C ADV, P1222
  • [9] KUSHIDA D, 2004, IEEJ T EIS, V124, P1296
  • [10] Lee S, 2002, 2002 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-3, PROCEEDINGS, P1499, DOI 10.1109/IRDS.2002.1043967