Air-braked cycle ergometers: Validity of the correction factor for barometric pressure

被引:6
作者
Finn, JP [1 ]
Maxwell, BF [1 ]
Withers, RT [1 ]
机构
[1] Flinders Univ S Australia, Sch Educ, Exercise Physiol Lab, Adelaide, SA 5001, Australia
关键词
air-braked ergometer; dynamic calibration rig; hypobaric chamber;
D O I
10.1055/s-2000-7416
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Barometric pressure exerts by far the greatest influence of the three environmental factors (barometric pressure, temperature and humidity) on power outputs from air-braked ergometers. The barometric pressure correction factor for power outputs from air-braked ergometers is in widespread use but apparently has never been empirically validated. Our experiment validated this correction factor by calibrating two air-braked cycle ergometers in a hypobaric chamber using a dynamic calibration rig. The results showed that if the power output correction for changes in air resistance at barometric pressures corresponding to altitudes of 38, 600, 1200 and 1800 m above mean sea level were applied, then the coefficients of variation were 0.8-1.9% over the range of 160-1597 W. The overall mean error was 3.0% but this included up to 0.73% for the propagated error that was associated with errors in the measurement of: a) temperature b) relative humidity c) barometric pressure d) force, distance and angular velocity by the dynamic calibration rig. The overall mean error therefore approximated the +/-2.0% of true load that was specified by the Laboratory Standards Assistance Scheme of the Australian Sports Commission. The validity of the correction factor for barometric pressure on power output was therefore demonstrated over the altitude range of 38 - 1800 m.
引用
收藏
页码:488 / 491
页数:4
相关论文
共 7 条
[1]  
Astrand P, 1986, TXB WORK PHYSL PHYSL, P366
[2]  
DAISH CB, 1972, PHYSICS BALL GAMES, P122
[3]   A macro-driven Excel template for determining the anaerobic capacity using an air-braked ergometer [J].
Finn, JP ;
Sainsbury, DA ;
Withers, RT .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1996, 13 (03) :179-189
[4]  
*HER MAJ STAT OFF, 1956, HDB MET INSTR 1, P21
[5]   Dynamic calibration of mechanically, air- and electromagnetically braked cycle ergometers [J].
Maxwell, BF ;
Withers, RT ;
Ilsley, AH ;
Wakim, MJ ;
Woods, GF ;
Day, L .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1998, 78 (04) :346-352
[6]  
TAYLOR JR, 1982, INTRO ERROR ANAL, P54
[7]   THE DYNAMIC CALIBRATION OF CYCLE ERGOMETERS [J].
WOODS, GF ;
DAY, L ;
WITHERS, RT ;
ILSLEY, AH ;
MAXWELL, BF .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1994, 15 (04) :168-171