Flexible amperometric transducers for biosensors based on a screen printed three electrode system

被引:58
作者
Erlenkötter, A
Kottbus, M
Chemnitius, GC
机构
[1] Inst Chemo & Biosensor, D-48149 Munster, Germany
[2] Univ Munster, Dept Inorgan Chem, D-48149 Munster, Germany
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2000年 / 481卷 / 01期
关键词
amperometry; thick film sensors; screen printed electrodes; platinum electrode; biosensors;
D O I
10.1016/S0022-0728(99)00491-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Screen printed three electrode sensors comprising a platinum working, a carbon counter and an Ag\AgCl pseudo reference electrode were developed employing polymer thick film inks. The sensors were constructed as amperometric transducers for multianalyte biosensors for use in batch, as well as in how through systems. The characteristics of the sensors were determined. The active surface area of the Pt working electrodes was determined using electrochemical and SEM studies. Cyclic voltammograms of the ferricyanide/ferrocyanide couple showed that the reaction was quasi-reversible at these electrodes. Although the surface was not ideal for this redox couple, the sensors proved to be reproducible and well suited for the determination of hydrogen peroxide and thus for biosensors based on oxidases as biologically active compounds. The combination of two pretreatment steps, an additional heat curing and an electrochemical preconditioning step, was found to be most helpful to reduce background current and settling time of the sensors. Different aspects of the changing surface composition are discussed. The sensors with optimized preconditioning showed linear ranges from 10 mu M up to at least 500 mu M hydrogen peroxide and sensitivities of 6.97 +/- 0.20 nA mu M-1 hydrogen peroxide for uncovered, 4.01 +/- 0.08 nA mu M-1 hydrogen peroxide for PCS/BSA membrane covered and 0.222 +/- 0.002 nA mu M-1 hydrogen peroxide for Nafion(R) coated platinum working electrodes. Moreover, optimized transducers with immobilized sarcosine oxidase (sensitivity: 2.30+/-0.07 nA mu M-1 sarcosine) demonstrated the feasibility of the sensor concept, the manufacturing and pretreatment processes for the development of enzyme sensors. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:82 / 94
页数:13
相关论文
共 48 条
[1]   MASS-PRODUCTION OF BIOSENSORS [J].
ALVAREZICAZA, M ;
BILITEWSKI, U .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :A525-A533
[2]   CHARGE-TRANSFER AT PARTIALLY BLOCKED SURFACES - A MODEL FOR THE CASE OF MICROSCOPIC ACTIVE AND INACTIVE SITES [J].
AMATORE, C ;
SAVEANT, JM ;
TESSIER, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 147 (1-2) :39-51
[3]   SURFACE CHARACTERIZATION OF THIN-FILM PLATINUM-ELECTRODES FOR BIOSENSORS BY MEANS OF CYCLIC VOLTAMMETRY AND LASER SNMS [J].
ASCHAUER, E ;
FASCHING, R ;
URBAN, G ;
NICOLUSSI, G ;
HUSINSKY, W .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 381 (1-2) :143-150
[4]  
Bachmann TT, 1998, ANAL LETT, V31, P2361
[5]   COPLANAR INTERDIGITATED BAND ELECTRODES FOR ELECTROSYNTHESIS .2. METHOXYLATION OF FURAN [J].
BELMONT, C ;
GIRAULT, HH .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1994, 24 (08) :719-724
[6]   ENZYME ELECTRODES FOR THE DETERMINATION OF CARBOHYDRATES IN FOOD [J].
BILITEWSKI, U ;
JAGER, A ;
RUGER, P ;
WEISE, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 15 (1-3) :113-118
[7]   SCREEN PRINTED GLUCOSE ELECTRODES BASED ON PLATINIZED CARBON PARTICLES AND GLUCOSE-OXIDASE [J].
CARDOSI, MF ;
BIRCH, SW .
ANALYTICA CHIMICA ACTA, 1993, 276 (01) :69-74
[8]   ELECTROCHEMICAL-BEHAVIOR OF MICROFABRICATED THICK-FILM ELECTRODES [J].
CHA, CS ;
SHAO, MJ ;
LIU, CC .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 2 (04) :277-281
[9]   Development of screen-printed enzyme electrodes for the estimation of fish quality [J].
Chemnitius, GC ;
Bilitewski, U .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 32 (02) :107-113
[10]  
CHEMNITIUS GC, 1994, THESIS U BRAUNSCHWEI