Physico-chemical approach to study organotin sorption-desorption during solid-phase microextraction

被引:16
作者
Aguerre, S [1 ]
Lespes, G [1 ]
Potin-Gautier, M [1 ]
机构
[1] Univ Pau & Pays Adour, CNRS, UMR 5034, Lab Chim Analyt Bioinorgan & Environm, F-64012 Pau, France
关键词
experimental design; kinetic studies; solid-phase microextraction; organotin compounds; humic substances;
D O I
10.1016/S0021-9673(03)00329-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Solid-phase microextraction (SPME) has become a real alternative to liquid-liquid extraction in the field of speciation of organometallic compounds. Despite the high performance of this preconcentration technique, matrix effects in natural samples can affect the analytical precision. In order to understand the origin of these disturbances and control the extraction step as best as possible, the sorption-desorption behaviour of organotins was studied. In the first part, this paper discusses the analytical problems encountered in the daily use of SPME due to the particular problems observed for phenyltins. The sorption profile of these compounds was modelled using experimental design methodology to confirm the first-order kinetics. Desorption of the compounds was also observed after a given time and could not be attributed to competition between organotin compounds. In the same way, butyl- and phenyltins were studied in the presence of humic substances, which acted as representatives of organic matter found in natural samples. These substances drastically decrease the extraction yields, but do not affect the sorption profile of butyl- and phenyltins. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:61 / 70
页数:10
相关论文
共 18 条
[1]   Speciation of organotins in environmental samples by SPME-GC: comparison of four specific detectors: FPD, PFPD, MIP-AES and ICP-MS [J].
Aguerre, S ;
Lespes, G ;
Desauziers, V ;
Potin-Gautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) :263-269
[2]   Solid phase microextraction (SPME): a new procedure for the control of butyl- and phenyltin pollution in the environment by GC-FPD [J].
Aguerre, S ;
Bancon-Montigny, C ;
Lespes, G ;
Potin-Gautier, M .
ANALYST, 2000, 125 (02) :263-268
[3]  
[Anonymous], 1988, METHODE PLANS EXPERI
[4]  
DEFATIMA M, 2000, J CHROMATOGR A, V889, P3
[5]  
FICINI J, 1978, STRUCTURE MATIERE
[6]   Matrix effect for several derivatives of benzene in water by solid phase microextraction (SPME) [J].
Jávorszky, E ;
Molnár, E ;
Torkos, K ;
Borossay, J .
CHROMATOGRAPHIA, 2000, 51 (1) :S328-S330
[7]  
MACCARTHY P, 1988, AQUATIC HUMIC SUBSTA
[8]   Absorption of hydrophobic compounds into the poly(dimethylsiloxane) coating of solid-phase microextraction fibers: High partition coefficients and fluorescence microscopy images [J].
Mayer, P ;
Vaes, WHJ ;
Hermens, JLM .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :459-464
[9]   Solid phase microextraction as a tool for trace element speciation [J].
Mester, Z ;
Sturgeon, R ;
Pawliszyn, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (03) :233-260
[10]   Determination of butyltin compounds in marine biological samples by enzymatic hydrolysis and HG-GC-QFAAS detection [J].
Pannier, F ;
Astruc, A ;
Astruc, M .
ANALYTICA CHIMICA ACTA, 1996, 327 (03) :287-293