Automated analysis of individual particles using a commercial capillary relectrophoresis system

被引:27
作者
Ahmadzadeh, H [1 ]
Dua, R [1 ]
Presley, AD [1 ]
Arriaga, EA [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
关键词
individual particle analysis; capillary electrophoresis; fluorescence detection; latex microspheres;
D O I
10.1016/j.chroma.2004.12.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary electrophoretic analysis of individual submicrometer size particles has been previously done using custom-built instruments. Despite that these instruments provide an excellent signal-to-noise ratio for individual particle detection, they are not capable of performing automated analyses of particles. Here we report the use of a commercial Beckman P/ACE MDQ capillary electrophoresis (CE) instrument with on-column laser-induced fluorescence (LIF) detection for the automated analysis of individual particles. The CE instrument was modified with an external I/O board that allowed for faster data acquisition rates (e.g. 100 Hz) than those available with the standard instrument settings (e.g. 4 Hz). A series of eight hydrodynamic injections expected to contain 32 6 particles, each followed by an electrophoretic separation at -300 V cm(-1) with data acquired at 100 Hz, showed 28 +/- 5 peaks corresponding to 31.9 particles as predicted by the statistical overlap theory. In contrast, a similar series of hydrodynamic injections followed by data acquisition at 4 Hz revealed only 8 +/- 3 peaks suggesting that the modified system is needed for individual particle analysis. Comparison of electropherograms obtained at both data acquisition rates also indicate: (i) similar migration time ranges; (ii) lower variation in the fluorescence intensity of individual peaks for 100 Hz;. and (iii) a better signal-to-noise ratio for 4 Hz raw data. S/N improved for 100 Hz when data were smoothed with a binomial filter but did not reach the S/N values previously reported for post-column LIF detection. The proof-of-principle of automated analysis of individual particles using a commercially available CE system described here opens exciting possibilities for those interested in the study and analyses of organelles. liposomes, and nanoparticles. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 37 条
[1]  
AHMADZADEH H, 2000, INSTRUMENTATION CAPI, P1
[2]   Determination of cell viability in single or mixed samples using capillary electrophoresis laser-induced fluorescence microfluidic systems [J].
Armstrong, DW ;
He, LF .
ANALYTICAL CHEMISTRY, 2001, 73 (19) :4551-4557
[3]   SUBATTOMOLE AMINO-ACID ANALYSIS BY CAPILLARY ZONE ELECTROPHORESIS AND LASER-INDUCED FLUORESCENCE [J].
CHENG, YF ;
DOVICHI, NJ .
SCIENCE, 1988, 242 (4878) :562-564
[4]  
CIPNOTTI L, 1983, J NUCL MED, V24, P768
[5]  
COULTER B, 2000, BECKMAN PACE SETTER, V4, P10
[6]   ORIGIN AND CHARACTERIZATION OF DEPARTURES FROM THE STATISTICAL-MODEL OF COMPONENT-PEAK OVERLAP IN CHROMATOGRAPHY [J].
DAVIS, JM ;
GIDDINGS, JC .
JOURNAL OF CHROMATOGRAPHY, 1984, 289 (APR) :277-298
[7]   STATISTICAL-METHOD FOR ESTIMATION OF NUMBER OF COMPONENTS FROM SINGLE COMPLEX CHROMATOGRAMS - APPLICATION TO EXPERIMENTAL CHROMATOGRAMS [J].
DAVIS, JM ;
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2178-2182
[8]   Justification of statistical overlap theory in programmed temperature gas chromatography: Thermodynamic origin of random distribution of retention times [J].
Davis, JM ;
Pompe, M ;
Samuel, C .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5700-5713
[9]  
DAVIS JM, 1983, ANAL CHEM, V55, P418, DOI 10.1021/ac00254a003
[10]   STATISTICAL-METHOD FOR ESTIMATION OF NUMBER OF COMPONENTS FROM SINGLE COMPLEX CHROMATOGRAMS - THEORY, COMPUTER-BASED TESTING, AND ANALYSIS OF ERRORS [J].
DAVIS, JM ;
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2168-2177