Use of pulmonary function tests in the diagnosis of occupational asthma

被引:13
作者
Anees, W [1 ]
机构
[1] Birmingham Heartlands Hosp, Occupat Lung Dis Unit, Birmingham B9 5SS, W Midlands, England
关键词
D O I
10.1016/S1081-1206(10)61649-3
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Objective: To discuss the different methods of assessing lung function measurements for the diagnosis of occupational asthma, focusing in particular on serial peak expiratory flow rate (PEFR) monitoring, including details on how PEFR records should be kept, plotted, and analyzed and limitations of the method. Data Sources: Published studies on the use of diagnostic methods in occupational asthma, expert opinion, and recently obtained data from studies performed at a large occupational lung disease clinic. Study Sources: The expert opinion of the author was used to select the relevant data for review. Results: Objective methods are necessary for the diagnosis of occupational asthma, since clinical history alone is not a satisfactory means of diagnosis. Serial PEFR monitoring has a high diagnostic sensitivity and specificity for occupational asthma and is more useful than evaluation of cross-shift change in forced expiratory volume in I second or change in nonspecific bronchial hyperresponsiveness. Interpretation is best performed by expert visual evaluation of plots of maximum, mean, and minimum daily PEFR readings. Conclusions: Despite some limitations of the method, serial PEFR monitoring is usually the most appropriate first-line investigation in workers suspected of having occupational asthma.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 24 条
[1]   Occupational asthma due to low molecular weight agents: eosinophilic and non-eosinophilic variants [J].
Anees, W ;
Huggins, V ;
Pavord, ID ;
Robertson, AS ;
Burge, PS .
THORAX, 2002, 57 (03) :231-236
[2]  
ANEES W, 2001, EUR RESPIR J, V18, pS281
[3]  
ANEES W, 2002, AM J RESP CRIT CARE, V165, pA524
[4]   Development of an expert system for the interpretation of serial peak expiratory flow measurements in the diagnosis of occupational asthma [J].
Burge, PS ;
Pantin, CFA ;
Newton, DT ;
Gannon, PFG ;
Bright, P ;
Belcher, J ;
McCoach, J ;
Baldwin, DR ;
Burge, CBSG .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1999, 56 (11) :758-764
[5]   OCCUPATIONAL ASTHMA IN AN ELECTRONICS FACTORY - CASE CONTROL STUDY TO EVALUATE ETIOLOGICAL FACTORS [J].
BURGE, PS ;
PERKS, WH ;
OBRIEN, IM ;
BURGE, A ;
HAWKINS, R ;
BROWN, D ;
GREEN, M .
THORAX, 1979, 34 (03) :300-307
[6]   PEAK FLOW-RATE RECORDS IN THE DIAGNOSIS OF OCCUPATIONAL ASTHMA DUE TO COLOPHONY [J].
BURGE, PS ;
OBRIEN, IM ;
HARRIES, MG .
THORAX, 1979, 34 (03) :308-316
[7]   PEAK FLOW-RATE RECORDS IN THE DIAGNOSIS OF OCCUPATIONAL ASTHMA DUE TO ISOCYANATES [J].
BURGE, PS ;
OBRIEN, IM ;
HARRIES, MG .
THORAX, 1979, 34 (03) :317-323
[8]   QUANTITATIVE VERSUS QUALITATIVE-ANALYSIS OF PEAK EXPIRATORY FLOW IN OCCUPATIONAL ASTHMA [J].
COTE, J ;
KENNEDY, S ;
CHANYEUNG, M .
THORAX, 1993, 48 (01) :48-51
[9]   SENSITIVITY AND SPECIFICITY OF PC20 AND PEAK EXPIRATORY FLOW-RATE IN CEDAR ASTHMA [J].
COTE, J ;
KENNEDY, S ;
CHANYEUNG, M .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1990, 85 (03) :592-598
[10]   Comparison between peak expiratory flow and expiratory volume in one second (FEV(1)) during bronchoconstriction induced by different stimuli [J].
Giannini, D ;
Paggiaro, PL ;
Moscato, G ;
Gherson, G ;
Bacci, E ;
Bancalari, L ;
Dente, FL ;
DiFranco, A ;
Vagaggini, B ;
Giuntini, C .
JOURNAL OF ASTHMA, 1997, 34 (02) :105-111