Enantioseparations in non-aqueous capillary electrochromatography using polysaccharide type chiral stationary phases

被引:70
作者
Girod, M [1 ]
Chankvetadze, B [1 ]
Blaschke, G [1 ]
机构
[1] Univ Munster, Inst Pharmaceut Chem, D-48149 Munster, Germany
关键词
enantiomer separations; chiral stationary phases; CEC; polysaccharide derivatives;
D O I
10.1016/S0021-9673(99)01204-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Enantioseparations of chiral compounds with different structures were studied in non-aqueous capillary electrochromatography (NAQ CEC). Three different polysaccharide derivatives, cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD), amylose bis(3,5-dimethylphenylcarbamate) (Chiralpak AD) and cellulose tris(4-methylbenzoate) (Chiralcel OJ) were used as chiral stationary phases (CSPs). Methanolic or ethanolic ammonium acetate solutions served as a mobile phase. The effect of the type of the CSP, the loading of the chiral selector on wide-pore aminopropyl derivatized silica gel and operational parameters such as apparent pH, applied voltage, etc. on the EOF and chromatographic characteristics (alpha, N, R-S) were studied. NAQ CEC represents a valuable alternative and an extension to chiral separations by HPLC with common-size columns as well as to capillary LC and CEC in aqueous buffers. (C) 2000 Elsevier Science BN. All rights reserved.
引用
收藏
页码:439 / 455
页数:17
相关论文
共 24 条
[1]  
[Anonymous], PRACTICAL HIGH PERFO
[2]  
Beale SC, 1998, ANAL CHEM, V70, p279R
[3]  
CHANKVETADZE B, 1997, CAPILLARY ELECTROPHO, P351
[4]   Influence of thermal annealing on the thermodynamic and mass transfer kinetic properties of D- and L-phenylalanine anilide on imprinted polymeric stationary phases [J].
Chen, YB ;
Kele, M ;
Sajonz, P ;
Sellergren, B ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :928-938
[5]   Dynamics of capillary electrochromatography - Experimental study on the electrosmotic flow and conductance in open and packed capillaries [J].
Choudhary, G ;
Horvath, C .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :161-183
[6]   Attempt to define the role of the length of the packed section in capillary electrochromatography [J].
Cikalo, MG ;
Bartle, KD ;
Myers, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (01) :25-34
[7]   Capillary electrochromatography [J].
Colon, LA ;
Guo, Y ;
Fermier, A .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :A461-A467
[8]  
DINGENEN J, PRACTICAL APPROACH C, P115
[9]   Adsorption isotherms of nonionic surfactants in SBA-15 measured by micro-column chromatography [J].
Findenegg, G. H. ;
Eltekov, A. Y. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) :236-240
[10]   DIRECT SEPARATION OF ENANTIOMERS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CELLULOSE TRIS(3,5-DIMETHYLPHENYLCARBAMATE) [J].
IKEDA, K ;
HAMASAKI, T ;
KOHNO, H ;
OGAWA, T ;
MATSUMOTO, T ;
SAKAI, JI .
CHEMISTRY LETTERS, 1989, (06) :1089-1090