Optimization of contrast-enhanced MR angiography of the hands with a timing bolus and elliptically reordered 3D pulse sequence

被引:19
作者
Winterer, JT [1 ]
Scheffler, K [1 ]
Paul, G [1 ]
Hauer, M [1 ]
Schäfer, O [1 ]
Altehoefer, C [1 ]
Laubenberger, J [1 ]
机构
[1] Univ Freiburg, Dept Diagnost Radiol, D-79106 Freiburg, Germany
关键词
magnetic resonance angiography; contrast media; gadolinium; hand; image processing; computer assisted diagnosis;
D O I
10.1097/00004728-200011000-00017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to optimize bolus administration and sequence setting in gadolinium-enhanced magnetic resonance (MR) angiography of the hands. Elliptically reordered three-dimensional (3D) spoiled gradient-echo sequence with non-slab-selective radio frequency excitation was optimized according to the measurements of arterial and venous time-signal curves in 21 patients. Great variations in bolus arrival time and arterio-venous transit time could be observed. In most patients high-quality arterial depiction could be obtained with minor venous contamination. Contrast-to-noise, spatial resolution, and selective arterial filling is still a challenge for 3D MR angiography of the hand but can be optimized using Gadolinium-BOPTA and a dedicated pulse sequence setting with exact bolus timing.
引用
收藏
页码:903 / 908
页数:6
相关论文
共 22 条
[1]  
Bartholomew, 1991, PERIPHERAL VASCULAR, P651
[2]   Routine myocardial revascularization with the radial artery: A multicenter experience [J].
Chen, AM ;
Brodman, RF ;
Frame, R ;
Graver, LM ;
Tranbaugh, RF ;
Banks, T ;
Hoffman, D ;
Palazzo, RS ;
Kline, GM ;
Stelzer, P ;
Harris, L ;
Sisto, D ;
Frymus, M ;
Frater, RWM ;
Furlong, P ;
Wasserman, F ;
Cohen, B .
JOURNAL OF CARDIAC SURGERY, 1998, 13 (05) :318-327
[3]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[4]  
FISCHER M, 1985, Z KARDIOL, V74, P298
[5]  
Gasser P, 1994, Schweiz Rundsch Med Prax, V83, P149
[6]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[7]   Quantifying digital vascular disease in patients with primary Raynaud's phenomenon and systemic sclerosis [J].
Herrick, AL ;
Clark, S .
ANNALS OF THE RHEUMATIC DISEASES, 1998, 57 (02) :70-78
[8]  
Ho ML, 1998, SCAND J RHEUMATOL, V27, P319
[9]   Simplified method for candidate selection for radial artery harvesting [J].
Johnson, WH ;
Cromartie, RS ;
Arrants, JE ;
Wuamett, JD ;
Holt, JB .
ANNALS OF THORACIC SURGERY, 1998, 65 (04) :1167-1167
[10]   Magnetic resonance angiography of the hand - A review [J].
Lee, VS ;
Lee, HM ;
Rofsky, NM .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :687-698