Comparison of chemical-activated luciferase gene expression bioassay and gas chromatography for PCB determination in human serum and follicular fluid

被引:43
作者
Pauwels, A
Cenijn, PH
Schepens, PJC
Brouwer, A
机构
[1] Univ Antwerp, Toxicol Pharmaceut Sci Ctr, B-2610 Antwerp, Belgium
[2] Agr Univ Wageningen, Dept Toxicol, Wageningen, Netherlands
[3] Free Univ Amsterdam, Inst Environm Studies, NL-1007 MC Amsterdam, Netherlands
关键词
CALUX bioassay; chemical-activated luciferase gene expression bioassay; dioxin-like compounds; follicular fluid; polychlorinated biphenyls (PCBs); serum; toxic equivalences;
D O I
10.1289/ehp.00108553
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We assessed exposure to dioxin-like compounds using chemical and bioassay analysis in different matrices in a female population. A total of 106 serum and 9 follicular fluid samples were collected from infertile women attending Centers for Reproductive Medicine in Belgium from 1996 to 1998. Major polychlorinated biphenyl (PCB) congeners were quantified by chemical analysis using gas chromatography with electron-capture detection, and the chemical-activated luciferase gene expression (CALUX) bioassay was used to determine the total dioxin-like toxic equivalence (TEQ) of mixtures of polyhalogenated aromatic hydrocarbons present in body fluids, such as serum and follicular fluid. To the best of our knowledge, this is the first investigation to determine TEQ values by the CALUX bioassay in follicular fluid. The TEQ levels in both matrices are well correlated (r = 0.83, p = 0.02). As the chemical and bioassay analysis executed in this study do not cover the same span of polyhalogenated aromatic hydrocarbons, we did not expect totally correlated results. Moreover, the sample workup and quantification of the analytes differed completely. Nonetheless, the TEQ values in human extracts correlated well with the sum of four major PCB congeners chemically determined in both serum and follicular fluid. These results indicate that the CALUX bioassay may serve as a simple, relatively inexpensive prescreening tool for exposure assessment in epidemiologic surveys.
引用
收藏
页码:553 / 557
页数:5
相关论文
共 30 条
[1]  
AARTS JMMJG, 1995, EUR J PHARM-ENVIRON, V293, P463
[2]   TOXIC EQUIVALENCY FACTORS FOR DIOXIN-LIKE PCBS - REPORT ON A WHO-ECEH AND IPCS CONSULTATION, DECEMBER 1993 [J].
AHLBORG, UG ;
BECKING, GC ;
BIRNBAUM, LS ;
BROUWER, A ;
DERKS, HJGM ;
FEELEY, M ;
GOLOR, G ;
HANBERG, A ;
LARSEN, JC ;
LIEM, AKD ;
SAFE, SH ;
SCHLATTER, C ;
WAERN, F ;
YOUNES, M ;
YRJANHEIKKI, E .
CHEMOSPHERE, 1994, 28 (06) :1049-1067
[3]  
[Anonymous], 1998, PERSISTENT ORGANIC P
[4]  
Bovee TFH, 1998, FOOD ADDIT CONTAM A, V15, P863, DOI 10.1080/02652039809374723
[5]  
BROUWER A, 1995, EUR J PHARM-ENVIRON, V293, P1
[6]  
Brouwer A. M., UNPUB
[7]   A CONGENER SPECIFIC METHOD FOR THE ANALYSIS OF POLYCHLORINATED-BIPHENYLS (PCBS) IN HUMAN-MILK [J].
DUARTEDAVIDSON, R ;
BURNETT, V ;
WATERHOUSE, KS ;
JONES, KC .
CHEMOSPHERE, 1991, 23 (02) :119-131
[8]   Species-specific recombinant cell lines as bioassay systems for the detection of 2,3,7,8-tetrachlorodibenzo-p-dioxin-like chemicals [J].
Garrison, PM ;
Tullis, K ;
Aarts, JMMJG ;
Brouwer, A ;
Giesy, JP ;
Denison, MS .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1996, 30 (02) :194-203
[9]   PCB AND DIOXIN LEVELS IN PLASMA AND HUMAN-MILK OF 418 DUTCH WOMEN AND THEIR INFANTS - PREDICTIVE VALUE OF PCB CONGENER LEVELS IN MATERNAL PLASMA FOR FETAL AND INFANTS EXPOSURE TO PCBS AND DIOXINS [J].
KOOPMANESSEBOOM, C ;
HUISMAN, M ;
WEISGLASKUPERUS, N ;
VANDERPAAUW, CG ;
TUINSTRA, LGMT ;
BOERSMA, ER ;
SAUER, PJJ .
CHEMOSPHERE, 1994, 28 (09) :1721-1732
[10]  
LIEM AKD, 1997, THESIS U UTRECHT