Dynamometer for rat plantar flexor muscles in vivo

被引:50
作者
Cutlip, RG
Stauber, WT
Willison, RH
McIntosh, TA
Means, KH
机构
[1] W Virginia Univ, Dept Physiol, Morgantown, WV 26506 USA
[2] W Virginia Univ, Dept Mech & Aerosp Engn, Morgantown, WV 26506 USA
[3] W Virginia Univ, Dept Neurol, Morgantown, WV 26506 USA
关键词
dynamometer; plantar flexor muscles; in vivo; servomotor; load cell; force output; rats;
D O I
10.1007/BF02525537
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A dynamometer is designed and fabricated to measure the force output during static and dynamic muscle actions of the plantar flexor muscles of anaesthetised rats in vivo. The design is based on a computer-controlled DC servomotor capable of angular velocities in excess of 17.5 rad s(-1). The system controls the range of motion, angular velocity and electrical stimulation of the muscles, while monitoring the force output at the plantar surface of the foot. The force output is measured by a piezo-electric load cell that is rated at 5 kg capacity. Angular velocity and position are measured by a DC tachometer and potentiometer, respectively. All measurement devices are linear (r(2)=0.9998). The design minimises inertial loading during high-speed angular motions, with a variation in force output of less than 0.2%. The dynamometer proves to be an accurate and reliable system for quantifying static and dynamic forces of rat plantar flexor muscles in vivo.
引用
收藏
页码:540 / 543
页数:4
相关论文
共 9 条
[1]   AN APPARATUS TO MEASURE INVIVO BIOMECHANICAL BEHAVIOR OF DORSIFLEXORS AND PLANTARFLEXORS OF MOUSE ANKLE [J].
ASHTONMILLER, JA ;
HE, YD ;
KADHIRESAN, VA ;
MCCUBBREY, DA ;
FAULKNER, JA .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 72 (03) :1205-1211
[2]   DYNAMIC PROPERTIES OF MAMMALIAN SKELETAL MUSCLE [J].
BAHLER, AS ;
FALES, JT ;
ZIERLER, KL .
JOURNAL OF GENERAL PHYSIOLOGY, 1968, 51 (03) :369-&
[3]  
FARRELL M, 1986, MED SCI SPORT EXER, V18, P44
[4]   INJURY TO SKELETAL-MUSCLES OF MICE BY FORCED LENGTHENING DURING CONTRACTIONS [J].
FAULKNER, JA ;
JONES, DA ;
ROUND, JM .
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES, 1989, 74 (05) :661-670
[5]   A NOTE ON THE APPLICATION AND EVALUATION OF THE BUCKLE TRANSDUCER FOR KNEE LIGAMENT FORCE MEASUREMENT [J].
LEWIS, JL ;
LEW, WD ;
SCHMIDT, J .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (02) :125-128
[6]   SELECTIVE DAMAGE OF FAST GLYCOLYTIC MUSCLE-FIBERS WITH ECCENTRIC CONTRACTION OF THE RABBIT TIBIALIS ANTERIOR [J].
LIEBER, RL ;
FRIDEN, J .
ACTA PHYSIOLOGICA SCANDINAVICA, 1988, 133 (04) :587-588
[7]   BIOMECHANICAL AND HISTOLOGICAL-EVALUATION OF MUSCLE AFTER CONTROLLED STRAIN INJURY [J].
NIKOLAOU, PK ;
MACDONALD, BL ;
GLISSON, RR ;
SEABER, AV ;
GARRETT, WE .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1987, 15 (01) :9-14
[8]   FORCES PRODUCED BY MEDIAL GASTROCNEMIUS AND SOLEUS MUSCLES DURING LOCOMOTION IN FREELY MOVING CATS [J].
WALMSLEY, B ;
HODGSON, JA ;
BURKE, RE .
JOURNAL OF NEUROPHYSIOLOGY, 1978, 41 (05) :1203-1216
[9]   MECHANICAL FACTORS IN THE INITIATION OF ECCENTRIC CONTRACTION-INDUCED INJURY IN RAT SOLEUS MUSCLE [J].
WARREN, GL ;
HAYES, DA ;
LOWE, DA ;
ARMSTRONG, RB .
JOURNAL OF PHYSIOLOGY-LONDON, 1993, 464 :457-475