Characterization and applications of CataCleave probe in real-time detection assays

被引:28
作者
Harvey, JJ
Lee, SP
Chan, EK
Kim, JH
Hwang, ES
Cha, CY
Knutson, JR
Han, MK [1 ]
机构
[1] Excimus Biotech Inc, Baltimore, MD 21202 USA
[2] Seoul Natl Univ, Coll Med, Dept Microbiol, Seoul, South Korea
[3] NHLBI, Biophys Chem Lab, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1016/j.ab.2004.05.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cycling probe technology (CPT), which utilizes a chimeric DNA-RNA-DNA probe and RNase H, is a rapid, isothermal probe amplification system for the detection of target DNA. Upon hybridization of the probe to its target DNA, RNase H cleaves the RNA portion of the DNA/RNA hybrid. Utilizing CPT, we designed a catalytically cleavable fluorescence probe (CataCleave probe) containing two internal fluorophores. Fluorescence intensity of the probe itself was weak due to Forster resonance energy transfer. Cleavage of the probe by RNase H in the presence of its target DNA caused enhancement of donor fluorescence, but this was not observed with nonspecific target DNA. Further, RNase H reactions with CataCleave probe exhibit a catalytic dose-dependent response to target DNA. This confirms the capability for the direct detection of specific target DNA through a signal amplification process. Moreover, CataCleave probe is also ideal for detecting DNA amplification processes, such as polymerase chain reaction (PCR) and isothermal rolling circle amplification (RCA). In fact, we observed signal enhancement proportional to the amount of RCA product formed. We were also able to monitor real-time PCR by measuring enhancement of donor fluorescence. Hence, CataCleave probe is useful for real-time monitoring of both isothermal and temperature-cycling nucleic acid amplification methods. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:246 / 255
页数:10
相关论文
共 34 条
[1]   Signal amplification of padlock probes by rolling circle replication [J].
Banér, J ;
Nilsson, M ;
Mendel-Hartvig, M ;
Landegren, U .
NUCLEIC ACIDS RESEARCH, 1998, 26 (22) :5073-5078
[3]  
Barany F, 1991, PCR Methods Appl, V1, P5, DOI 10.1101/gr.1.1.5
[4]   Rapid detection of the mecA gene in methicillin resistant staphylococci using a colorimetric Cycling Probe Technology [J].
Bekkaoui, F ;
McNevin, JP ;
Leung, CH ;
Peterson, GJ ;
Patel, A ;
Bhatt, RS ;
Bryan, RN .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1999, 34 (02) :83-90
[5]   NUCLEIC-ACID SEQUENCE-BASED AMPLIFICATION [J].
COMPTON, J .
NATURE, 1991, 350 (6313) :91-92
[6]  
Crouch R.J., 1993, NUCLEASES, P341
[7]   Rapid amplification of plasmid and phage DNA using phi29 DNA polymerase and multiply-primed rolling circle amplification [J].
Dean, FB ;
Nelson, JR ;
Giesler, TL ;
Lasken, RS .
GENOME RESEARCH, 2001, 11 (06) :1095-1099
[8]  
DUCK P, 1990, BIOTECHNIQUES, V9, P142
[9]   ROLLING REPLICATION OF SHORT DNA CIRCLES [J].
FIRE, A ;
XU, SQ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (10) :4641-4645
[10]   Rapid solid-phase immunoassay for detection of methicillin-resistant Staphylococcus aureus using cycling probe technology [J].
Fong, WK ;
Modrusan, Z ;
McNevin, JP ;
Marostenmaki, J ;
Zin, B ;
Bekkaoui, F .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (07) :2525-2529