Microvascular BOLD contribution at 4 and 7 T in the human brain: Gradient-echo and spin-echo fMRI with suppression of blood effects

被引:267
作者
Duong, TQ [1 ]
Yacoub, E [1 ]
Adriany, G [1 ]
Hu, XP [1 ]
Ugurbil, K [1 ]
Kim, SG [1 ]
机构
[1] Univ Minnesota, Sch Med, Ctr Magnet Resonance Res, Dept Radiol, Minneapolis, MN 55455 USA
关键词
spatial specificity; brain mapping; high magnetic fields; diffusion-weighting;
D O I
10.1002/mrm.10472
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The BOLD signal consists of an intravascular (IV) and an extravascular (EV) component from both small and large vessels. Their relative contributions are dependent on field strength, imaging technique, and echo time. The IV and EV contributions were investigated in the human visual cortex at 4 and 7 T using spin-echo and gradient-echo BOLD fMRI with and without suppression of blood effects. Spin-echo acquisition suppresses EV BOLD from large veins and reflects predominantly blood T-2 changes and EV BOLD signal from small blood vessels. At a short echo time (32 ms), diffusion gradient-based suppression of blood signals resulted in a 75% and 20% decrease in spin-echo BOLD changes at 4 T and 7 T, respectively. However, at echo times (55-65 ms) approximating tissue T-2 typically used for optimal BOLD contrast, these gradients had much smaller effects at both fields, consistent with the decreasing blood T-2 with increasing field strength. Gradient-echo BOLD percent changes, with relatively long echo times at both fields, were virtually unaffected by gradients that attenuated the blood contribution because the EV BOLD surrounding both large and small vessels dominated. These results suggest that spin-echo BOLD fMRI at 4 and 7 T, with TE approximating tissue T-2, significantly reduces nonspecific mapping signals from large vessels and significantly accentuates microvasculature contributions. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:1019 / 1027
页数:9
相关论文
共 48 条
[1]   SPIN-ECHO AND GRADIENT-ECHO EPI OF HUMAN BRAIN ACTIVATION USING BOLD CONTRAST - A COMPARATIVE-STUDY AT 1.5 T [J].
BANDETTINI, PA ;
WONG, EC ;
JESMANOWICZ, A ;
HINKS, RS ;
HYDE, JS .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :12-20
[2]  
Barth M, 1997, CELL MOL BIOL, V43, P783
[3]   In vivo 1H2O T2† measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI:: Detection of microscopic susceptibility contrast [J].
Bartha, R ;
Michaeli, S ;
Merkle, H ;
Adriany, G ;
Andersen, P ;
Chen, W ;
Ugurbil, K ;
Garwood, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :742-750
[4]   THE INTRAVASCULAR CONTRIBUTION TO FMRI SIGNAL CHANGE - MONTE-CARLO MODELING AND DIFFUSION-WEIGHTED STUDIES IN-VIVO [J].
BOXERMAN, JL ;
BANDETTINI, PA ;
KWONG, KK ;
BAKER, JR ;
DAVIS, TL ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :4-10
[5]   MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[6]   T1 AND T2 MEASUREMENTS ON A 1.5-T COMMERCIAL MR IMAGER [J].
BREGER, RK ;
RIMM, AA ;
FISCHER, ME ;
PAPKE, RA ;
HAUGHTON, VM .
RADIOLOGY, 1989, 171 (01) :273-276
[7]   MAGNETIC-RELAXATION IN BLOOD AND BLOOD-CLOTS [J].
BRYANT, RG ;
MARILL, K ;
BLACKMORE, C ;
FRANCIS, C .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :133-144
[8]   Transient decrease in water diffusion observed in human occipital cortex during visual stimulation [J].
Darquié, A ;
Poline, JB ;
Poupon, C ;
Saint-Jalmes, H ;
Le Bihan, D .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (16) :9391-9395
[9]  
Duong TQ, 2000, MAGN RESON MED, V44, P231, DOI 10.1002/1522-2594(200008)44:2<231::AID-MRM10>3.0.CO
[10]  
2-T