Automated computerized scheme for detection of unruptured intracranial aneurysms in three-dimensional magnetic resonance angiography

被引:75
作者
Arimura, H
Li, Q
Korogi, Y
Hirai, T
Abe, H
Yamashita, Y
Katsuragawa, S
Ikeda, R
Doi, K
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Hosp Occupat & Environm Hlth, Dept Radiol, Kitakyushu, Fukuoka, Japan
[3] Kumamoto Univ Hosp, Dept Radiol, Kumamoto, Japan
关键词
computer-aided diagnosis (CAD); unruptured intracranial aneurysm; magnetic resonance angiography (MRA); selective enhancement filter;
D O I
10.1016/j.acra.2004.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. A computerized scheme for automated detection of unruptured intracranial aneurysms in magnetic resonance angiography was developed based on the use of a three-dimensional selective enhancement filter for dots (aneurysms). Materials and Methods. Twenty-nine cases with 36 unruptured aneurysms (diameter, 3 to 26 mm; mean, 6.6 mm) and 31 non-aneurysm cases were used in this study. The isotropic 3-dimensional magnetic resonance angiography images with 400 x 400 x 128 voxels (voxel size, 0.5 mm) were processed by use of the selective enhancement filter. The initial candidates were identified by use of a multiple gray-level thresholding technique on the dot-enhanced images and a region-growing technique with monitoring some image features. All candidates were classified into four types of candidates according to the size and local structures based on the effective diameter and skeleton image of each candidate (ie, large candidates and three types of small candidates including short-branch type, single-vessel type, and bifurcation type). In each group, a number of false-positives were removed by use of different rules on localized image features related to gray levels and morphology. Linear discriminant analysis was used for further removal of false-positives. Results. With this computer-aided diagnostic scheme, all of 36 aneurysms were correctly detected with 2.4 false-positives per patient based on a leave-one-out-by-patient test method. Conclusion. This computer-aided diagnostic system would be useful in assisting radiologists for the detection of intracranial aneurysms in magnetic resonance angiography. (C) AUR, 2004.
引用
收藏
页码:1093 / 1104
页数:12
相关论文
共 34 条
[1]   Automated computerized scheme for distinction between benign and malignant solitary pulmonary nodules on chest images [J].
Aoyama, M ;
Li, Q ;
Katsuragawa, S ;
MacMahon, H ;
Doi, K .
MEDICAL PHYSICS, 2002, 29 (05) :701-708
[2]   Evaluation of cerebral aneurysms with MR-angiography - Our experience and a review of the literature [J].
Aprile, I ;
Biasizzo, E ;
Lavaroni, A ;
Budai, R ;
Iaiza, F ;
Janes, PP ;
Fabris, G .
RIVISTA DI NEURORADIOLOGIA, 1996, 9 (05) :541-550
[3]   Development of CAD scheme for automated detection of intracranial aneurysms in magnetic resonance angiography [J].
Arimura, H ;
Li, Q ;
Korogi, Y ;
Hirai, T ;
Abe, H ;
Yamashita, Y ;
Katsuragawa, S ;
Ikeda, R ;
Doi, K .
CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 :1015-1020
[4]   INITIAL AND RECURRENT BLEEDING ARE THE MAJOR CAUSES OF DEATH FOLLOWING SUBARACHNOID HEMORRHAGE [J].
BRODERICK, JP ;
BROTT, TG ;
DULDNER, JE ;
TOMSICK, T ;
LEACH, A .
STROKE, 1994, 25 (07) :1342-1347
[5]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .1. AUTOMATED DETECTION OF MICROCALCIFICATIONS IN MAMMOGRAPHY [J].
CHAN, HP ;
DOI, K ;
GALHOTRA, S ;
VYBORNY, CJ ;
MACMAHON, H ;
JOKICH, PM .
MEDICAL PHYSICS, 1987, 14 (04) :538-548
[6]   IMPROVEMENT IN RADIOLOGISTS DETECTION OF CLUSTERED MICROCALCIFICATIONS ON MAMMOGRAMS - THE POTENTIAL OF COMPUTER-AIDED DIAGNOSIS [J].
CHAN, HP ;
DOI, K ;
VYBORNY, CJ ;
SCHMIDT, RA ;
METZ, CE ;
LAM, KL ;
OGURA, T ;
WU, YZ ;
MACMAHON, H .
INVESTIGATIVE RADIOLOGY, 1990, 25 (10) :1102-1110
[7]   IMPACT OF EARLY SURGERY ON OUTCOME AFTER ANEURYSMAL SUBARACHNOID HEMORRHAGE - A POPULATION-BASED STUDY [J].
FOGELHOLM, R ;
HERNESNIEMI, J ;
VAPALAHTI, M .
STROKE, 1993, 24 (11) :1649-1654
[8]   Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center [J].
Freer, TW ;
Ulissey, MJ .
RADIOLOGY, 2001, 220 (03) :781-786
[9]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .3. AUTOMATED DETECTION OF NODULES IN PERIPHERAL LUNG FIELDS [J].
GIGER, ML ;
DOI, K ;
MACMAHON, H .
MEDICAL PHYSICS, 1988, 15 (02) :158-166
[10]   ANEURYSMAL SUBARACHNOID HEMORRHAGE - COMPLICATIONS AND OUTCOME IN A HOSPITAL POPULATION [J].
HIJDRA, A ;
BRAAKMAN, R ;
VANGIJN, J ;
VERMEULEN, M ;
VANCREVEL, H .
STROKE, 1987, 18 (06) :1061-1067