Compression stimuli increase the efficacy of breast pump function

被引:19
作者
Alekseev, NP
Ilyin, VI
Yaroslavski, VK
Gaidukov, SN
Tikhonova, TK
Specivcev, YA
Omelyanjuk, EV
Tkachenko, NN
机构
[1] St Petersburg State Univ, Inst Physiol, St Petersburg 199034, Russia
[2] St Petersburg Med Acad Pediat, Dept Obstet & Gynecol, St Petersburg, Russia
[3] RAMN, DO Ott Inst Obstet & Gynecol, St Petersburg, Russia
来源
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY | 1998年 / 77卷 / 02期
关键词
breast pump; milk-ejection and milk-production reflex; compression and vacuum stimuli;
D O I
10.1016/S0301-2115(97)00269-8
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The dynamics of milk ejection and also prolactin concentration in the blood during milk expression by means of a breast pump were studied in 82 lactating women. Study design: The design of the breast pump used in this study is new. It is based on the correlation with the amplitude, duration and frequency of vacuum and compression stimuli formed by the baby's mouth apparatus during the suckling process. Results: It was found that during continuous co-action of the vacuum and compression stimuli at a frequency of 1 cycle per second, the rate of milk ejection from the breast changed periodically. The highest rates of milk ejection coincided with the greatest rises in intramammary pressure. When the compression stimulus was turned off, leaving only the vacuum, the period of the first rise in pressure increased 1.5-2 fold, with a 1.5-2 fold reduction in the milk ejection rate as compared with the normal function of the boast pump. The basal prolactin level on day 3 and 5 post delivery in women who used a breast pump was not significantly different from that of puerperal women who only breast-fed their babies. Prolactin concentration in the blood of puerperal women did not change within the 5-6 min of expression and stimulation with the breast pump. The prolactin level began to increase by the 10th minute, whereas by the 25th minute it exceeded the initial concentration 1.3-1.5-fold. Conclusion: It is suggested that by introducing a tactile component to the mechanism of the breast pump, milk secretion is enhanced, as well as stimulating the breast milk flow. This directly improves the dynamics of breast milk expression. (C) 1998 Elsevier Science Ireland Ltd.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 31 条
[1]  
AKRE J, 1989, B WORLD HEALTH ORGAN, V67, P19
[2]   SUCKING BEHAVIOR AND MILK INTAKE IN JAUNDICED NEONATES [J].
ALEXANDER, GS ;
ROBERTS, SA .
EARLY HUMAN DEVELOPMENT, 1988, 16 (01) :73-84
[3]  
ALIPOV AA, 1988, LACTATION WOMEN
[4]   INITIATION OF HUMAN LACTATION AND PROLACTIN RESPONSE TO SUCKLING [J].
AONO, T ;
SHIOJI, T ;
SHODA, T ;
KURACHI, K .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1977, 44 (06) :1101-1106
[5]  
ARDRAN G M, 1959, Acta Paediatr, V48, P261
[6]  
BEZZUBTZEV VS, 1981, MODERN ACHIEVEMENTS, P91
[7]  
BOWENJONES A, 1982, DEV MED CHILD NEUROL, V24, P626
[8]   RELATIONSHIP BETWEEN PLASMA PROFILES OF OXYTOCIN AND ADRENOCORTICOTROPIC HORMONE DURING SUCKLING OR BREAST STIMULATION IN WOMEN [J].
CHIODERA, P ;
SALVARANI, C ;
BACCHIMODENA, A ;
SPALLANZANI, R ;
CIGARINI, C ;
ALBONI, A ;
GARDINI, E ;
COIRO, V .
HORMONE RESEARCH, 1991, 35 (3-4) :119-123
[9]  
COBO E, 1967, American Journal of Obstetrics and Gynecology, V97, P519
[10]   SUCKING AND SWALLOWING IN INFANTS [J].
COLLEY, JRT ;
CREAMER, B .
BRITISH MEDICAL JOURNAL, 1958, 2 (AUG16) :422-423