Use of conventional and self-adjusting nasal continuous positive airway pressure for treatment of severe obstructive sleep apnea syndrome - A comparative study

被引:78
作者
Konermann, M
Sanner, BM
Vyleta, M
Laschewski, F
Groetz, J
Sturm, A
Zidek, W
机构
[1] Marienkrankenhaus, D-34127 Kassel, Germany
[2] Ruhr Univ Bochum, Marienhosp, Dept Med, D-4630 Bochum, Germany
关键词
nCPAP pressure; nCPAP therapy; obstructive sleep apnea syndrome; self-adjusting nCPAP;
D O I
10.1378/chest.113.3.714
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: To compare conventional and self-adjusting nasal continuous positive airway pressure (nCPAP) therapy in patients with severe obstructive sleep apnea syndrome with respect to suppression of respiratory disturbances, quality of sleep, mean mask pressure, and patient compliance. Design: Cohort study of consecutive patients with obstructive sleep apnea syndrome, single-blinded. Setting: Clinical sleep laboratory in Germany. Patients: Fifty patients (44 men, 6 women who ranged in age from 35 to 71 years) with polysomnographically confirmed severe obstructive sleep apnea syndrome (respiratory disturbance index [RDI], >20/h). Measurements and interventions: After baseline polysomnography, patients were randomly treated with nCPAP either in conventional (group 1) or in automatically adjusting (group 2) mode. Three to 6 months after adjustment, all patients underwent polysomnography again. They also were examined with a portable monitoring device and received a questionnaire on subjective well-being and device evaluation. Results: Anthropometric and respiratory data were comparable in both groups; body mass index had not changed significantly in the follow-up. RDI dropped by 91.5% (from 38.3+/-13.9/h to 3.6+/-4.4/h) in conventional and 93.6% (from 35.5+/-9.6/h to 2.4+/-1.6/h) in self-adjusting mode (statistically not significant [NS]). Sleep efficiency decreased 4.0% in conventional and increased by 2.0% in self-adjusting mode (NS). In both groups, normal sleep structure was largely restored. Mean mask pressure was 8.1+/-2.5 cm H2O in group 1 and 6.5+/-1.7 cm H2O in group 2 (p<0.01). Patient compliance in terms of nights per week of mask appliance was better in the self-adjusting mode (5.7+/-0.7 to 6.5+/-0.4; p<0.01). Conclusion: Self-adjusting mCPAP demonstrates the same reliability in suppression of respiratory disturbances as fired-mask pressure therapy. Sleep quality is slightly superior, patient compliance is highly significantly better.
引用
收藏
页码:714 / 718
页数:5
相关论文
共 17 条
[1]   OBSTRUCTIVE SLEEP-APNEA - A COMPARISON OF CONTINUOUS POSITIVE AIRWAY PRESSURE AND SURGICAL-TREATMENT [J].
ANAND, VK ;
FERGUSON, PW ;
SCHOEN, LS .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1991, 105 (03) :382-390
[2]  
BERTHONJONES M, 1993, SLEEP, V16, P120
[3]   A COMPARATIVE-STUDY OF TREATMENTS FOR POSITIONAL SLEEP-APNEA [J].
CARTWRIGHT, R ;
RISTANOVIC, R ;
DIAZ, F ;
CALDARELLI, D ;
ALDER, G .
SLEEP, 1991, 14 (06) :546-552
[4]   COMPLIANCE WITH CPAP THERAPY IN PATIENTS WITH THE SLEEP APNOEA/HYPOPNOEA SYNDROME [J].
ENGLEMAN, HM ;
MARTIN, SE ;
DOUGLAS, NJ .
THORAX, 1994, 49 (03) :263-266
[5]   SLEEP-APNEA AND BODY POSITION DURING SLEEP [J].
GEORGE, CF ;
MILLAR, TW ;
KRYGER, MH .
SLEEP, 1988, 11 (01) :90-99
[6]   UPPER AIRWAY CLOSING PRESSURES IN SNORERS [J].
ISSA, FG ;
SULLIVAN, CE .
JOURNAL OF APPLIED PHYSIOLOGY, 1984, 57 (02) :528-535
[7]  
KONERMANN M, 1995, MED KLIN, V90, P480
[8]   CONSTANCY OF NCPAP PRESSURES IN LONG-TERM MONITORING OF PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA [J].
KONERMANN, M ;
SANNER, B ;
BURMANNURBANEK, M ;
HORSTENSMEYER, D ;
LASCHEWSKI, F .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1995, 120 (05) :125-129
[9]   LEFT-VENTRICULAR EJECTION FRACTION IN OBSTRUCTIVE SLEEP-APNEA - EFFECTS OF LONG-TERM TREATMENT WITH NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE [J].
KRIEGER, J ;
GRUCKER, D ;
SFORZA, E ;
CHAMBRON, J ;
KURTZ, D .
CHEST, 1991, 100 (04) :917-921
[10]   LONG-TERM OUTCOME FOR OBSTRUCTIVE SLEEP-APNEA SYNDROME PATIENTS - MORTALITY [J].
PARTINEN, M ;
JAMIESON, A ;
GUILLEMINAULT, C .
CHEST, 1988, 94 (06) :1200-1204