Evaluation of unfolded-partial least-squares coupled to residual trilinearization for four-way calibration of folic acid and methotrexate in human serum samples

被引:39
作者
de la Pena, A. Munoz [1 ]
Duran Meras, I.
Jimenez Giron, A.
Goicoechea, H. C.
机构
[1] Univ Extremadura, Dept Analyt Chem, Badajoz 06071, Spain
[2] Univ Nacl Litoral, Fac Bioquim & Ciencias Biol, Catedra Quiam Analit 1, LADAQ, Santa Fe, Argentina
关键词
four-way data; unfolded-partial least-squares; residual trilinearization; folic acid; methotrexate; human serum;
D O I
10.1016/j.talanta.2007.01.018
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
The combination of unfolded-partial least-squares (U-PLS) with a recently proposed separate procedure, known as residual trilinearization (RTL), has been successfully employed for four-way data calibration. The chemometric method employs the evolution of excitation-emission matrices (EEMs) with time, for the resolution of folic acid-methotrexate mixtures, in human serum samples. The fluorogenic products monitored correspond to the oxidation of the studied analytes with potassium permanganate, in slightly acidic medium. The reaction is developed in 7 min and followed using a fast-scanning spectrofluorimeter, capable of recording each complete EEM in 12 s. This allows the acquisition of 10 successive EEMs, at different reaction times, during the development of the oxidation reaction, given rise to the four-way data set employed. The procedure, which had been previously reported for urine determination, is extended to serum analysis in this work. The combination of U-PLS/RTL is providing enhanced predictive results in comparison with standard methods as PARAFAC and N-PLS, in the presence of human serum, where significant unexpected components and or inner filter effects may occur. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1261 / 1268
页数:8
相关论文
共 55 条
[1]
Albertioni F, 1996, CLIN CHEM, V42, P39
[2]
SIMULTANEOUS QUANTITATION OF METHOTREXATE AND ITS 2 MAIN METABOLITES IN BIOLOGICAL-FLUIDS BY A NOVEL SOLID-PHASE EXTRACTION PROCEDURE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ALBERTIONI, F ;
PETTERSSON, B ;
BECK, O ;
RASK, C ;
SEIDEMAN, P ;
PETERSON, C .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 665 (01) :163-170
[3]
Practical aspects of PARAFAC modeling of fluorescence excitation-emission data [J].
Andersen, CM ;
Bro, R .
JOURNAL OF CHEMOMETRICS, 2003, 17 (04) :200-215
[4]
[Anonymous], 1987, BINDING CONSTANTS ME
[5]
Trilinear least-squares and unfolded-PLS coupled to residual trilinearization:: New chemometric tools for the analysis of four-way instrumental data [J].
Arancibia, JA ;
Olivieri, AC ;
Gil, DB ;
Mansilla, AE ;
Durán-Merás, B ;
de la Peña, AM .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 80 (01) :77-86
[6]
TRACE ANALYSIS OF METHOTREXATE AND 7-HYDROXYMETHOTREXATE IN HUMAN PLASMA AND URINE BY A NOVEL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD [J].
BECK, O ;
SEIDEMAN, P ;
WENNBERG, M ;
PETERSON, C .
THERAPEUTIC DRUG MONITORING, 1991, 13 (06) :528-532
[7]
ODE TO METHOTREXATE [J].
BERTINO, JR .
JOURNAL OF CLINICAL ONCOLOGY, 1993, 11 (01) :5-14
[8]
Second-order advantage achieved by unfolded-partial least-squares/residual bilinearization modeling of excitation-emission fluorescence data presenting inner filter effects [J].
Bohoyo Gil, Diego ;
Munoz de la Pena, Arsenio ;
Arancibia, Juan A. ;
Escandar, Graciela M. ;
Olivieri, Alejandro C. .
ANALYTICAL CHEMISTRY, 2006, 78 (23) :8051-8058
[9]
A new efficient method for determining the number of components in PARAFAC models [J].
Bro, R ;
Kiers, HAL .
JOURNAL OF CHEMOMETRICS, 2003, 17 (05) :274-286
[10]
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.0.CO