Assessing the implant/bone interface by using natural frequency analysis

被引:69
作者
Huang, HM
Pan, LC
Lee, SY
Chiu, CL
Fan, KH
Ho, KN
机构
[1] Taipei Med Coll, Grad Inst Oral Rehabil Sci, Taipei, Taiwan
[2] Taipei Med Coll, Sch Med Technol, Taipei, Taiwan
[3] Taipei Med Coll, Sch Med, Taipei, Taiwan
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 2000年 / 90卷 / 03期
关键词
D O I
10.1067/moe.2000.108918
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Objective. A number of techniques have been proposed for detecting the stability of dental implants. However, the clinical applicability of those methods is still limited. The purpose of this study was to evaluate a new innovative, noninvasive, minimum-contact method for the stability assessment of dental implants. Study design. Natural frequency is a physical property of a structure, which is strongly related to its boundary conditions. In this study, a modal testing technique was carried out to measure the natural frequency of dental implants. The implants were fixed by a metal clamp stand and were excited to vibrate by an impulse hammer. A noncontact piezoelectric microphone then acoustically acquired the vibration responses of the implants. Natural frequencies of the tested implants were recorded under various clamping forces and clamping levels. Results. Natural frequencies of the tested implants were concentrated from 8 to 19 kHz under different boundary conditions. On the other hand, the natural frequency values decreased when boundary levels and boundary force were reduced: Linear relationships (P <.005) were found between response frequencies and the degree of implant stability. Conclusions. Our results show that the boundary status of an implant can be monitored by detecting its natural frequency. A noncontact transducer used in this study can also serve as a useful tool for future clinical investigations.
引用
收藏
页码:285 / 291
页数:7
相关论文
共 39 条
[1]
CLINICAL-RESULTS OF OSSEOINTEGRATED IMPLANTS SUPPORTING FIXED PROSTHESES IN EDENTULOUS JAWS [J].
ADELL, R .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (02) :251-254
[2]
MARGINAL TISSUE-REACTIONS AT OSSEOINTEGRATED TITANIUM FIXTURES .1. A 3-YEAR LONGITUDINAL PROSPECTIVE-STUDY [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI ;
LINDHE, J ;
ERIKSSON, B ;
SBORDONE, L .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1986, 15 (01) :39-52
[3]
A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[4]
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[5]
OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[6]
Carlsson L, 1988, Int J Oral Maxillofac Implants, V3, P21
[7]
Carr A B, 1995, Int J Prosthodont, V8, P15
[8]
DEHAMI K, 1995, INT J ORAL MAXILLOF, V10, P221
[9]
Elias J J, 1996, Int J Oral Maxillofac Implants, V11, P728
[10]
EWINS DJ, 1986, MODAL TESTING THEORY, P88