Localization of Pulmonary Nodules Using Navigation Bronchoscope and a Near-Infrared Fluorescence Thoracoscope

被引:126
作者
Anayama, Takashi
Qiu, Jimmy
Chan, Harley
Nakajima, Takahiro
Weersink, Robert
Daly, Michael
McConnell, Judy
Waddell, Thomas
Keshavjee, Shaf
Jaffray, David
Irish, Jonathan C.
Hirohashi, Kentaro
Wada, Hironobu
Orihashi, Kazumasa
Yasufuku, Kazuhiro
机构
[1] Univ Hlth Network, Toronto Gen Hosp, Div Thorac Surg, Dept Surg, Toronto, ON M5G 2C4, Canada
[2] Kochi Univ, Kochi Med Sch, Dept Surg 2, Kochi 780, Japan
[3] Univ Hlth Network, Princess Margaret Hosp, Dept Radiat Med, Toronto, ON M5G 2C4, Canada
[4] Princess Margaret Canc Ctr, Dept Otolaryngol Head & Neck Surgery Surg Oncol, Toronto, ON, Canada
关键词
INDOCYANINE GREEN FLUORESCENCE; EARLY LUNG-CANCER; SPIRAL COMPUTED-TOMOGRAPHY; LYMPH-NODE BIOPSY; CONE-BEAM CT; ASYMPTOMATIC SMOKERS; SURGERY; RESECTION; MICROCOILS; ARM;
D O I
10.1016/j.athoracsur.2014.07.050
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background. Video-assisted thoracoscopic wedge resection of multiple small, non-visible, and nonpalpable pulmonary nodules is a clinical challenge. We propose an ultra-minimally invasive technique for localization of pulmonary nodules using the electromagnetic navigation bronchoscope (ENB)-guided transbronchial indocyanine green (ICG) injection and intraoperative fluorescence detection with a near-infrared (NIR) fluorescence thoracoscope. Methods. Fluorescence properties of ICG topically injected into the lung parenchyma were determined using a resected porcine lung. The combination of ENB-guided ICG injection and NIR fluorescence detection was tested using a live porcine model. An electromagnetic sensor integrated flexible bronchoscope was geometrically registered to the three-dimensional chest computed tomographic image data by way of a real-time electromagnetic tracking system. The ICG mixed with iopamidol was injected into the pulmonary nodules by ENB guidance; ICG fluorescence was visualized by a near-infrared (NIR) thoracoscope. Results. The ICG existing under 24-mm depth of inflated lung was detectable by the NIR fluorescence thoracoscope. The size of the fluorescence spot made by 0.1 mL of ICG was 10.4 +/- 2.2 mm. An ICG or iopamidol spot remained at the injected point of the lung for more than 6 hours in vivo. The ICG fluorescence spot injected into the pulmonary nodule with ENB guidance was identified at the pulmonary nodule with the NIR thoracoscope. Conclusions. The ENB-guided transbronchial ICG injection and intraoperative NIR thoracoscopic detection is a feasible method to localize multiple pulmonary nodules. (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:224 / 230
页数:7
相关论文
共 35 条
[1]
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[2]
Volumetric characterization of the Aurora magnetic tracker system for image-guided transorbital endoscopic procedures [J].
Atuegwu, N. C. ;
Galloway, R. L. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (16) :4355-4368
[3]
Computed Tomography-Guided Preoperative Radiotracer Localization of Nonpalpable Lung Nodules [J].
Bellomi, Massimo ;
Veronesi, Giulia ;
Trifiro, Giuseppe ;
Brambilla, Sarah ;
Bonello, Luke ;
Preda, Lorenzo ;
Casiraghi, Monica ;
Borri, Alessandro ;
Paganelli, Giovanni ;
Spaggiari, Lorenzo .
ANNALS OF THORACIC SURGERY, 2010, 90 (06) :1759-1765
[4]
Crane L.M., 2010, J Vis Exp
[5]
Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype [J].
Daly, M. J. ;
Siewerdsen, J. H. ;
Moseley, D. J. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2006, 33 (10) :3767-3780
[6]
Daly MJ, 2010, SPIE MED IMAGING, P7625
[7]
Screening for early lung cancer with low-dose spiral computed tomography: results of annual follow-up examinations in asymptomatic smokers [J].
Diederich, S ;
Thomas, M ;
Semik, M ;
Lenzen, H ;
Roos, N ;
Weber, A ;
Heindel, W ;
Wormanns, D .
EUROPEAN RADIOLOGY, 2004, 14 (04) :691-702
[8]
Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers [J].
Diederich, S ;
Wormanns, D ;
Semik, M ;
Thomas, M ;
Lenzen, H ;
Roos, N ;
Heindel, W .
RADIOLOGY, 2002, 222 (03) :773-781
[9]
Indocyanine green fluorescence-navigated sentinel node biopsy showed higher sensitivity than the radioisotope or blue dye method, which may help to reduce false-negative cases in skin cancer [J].
Fujisawa, Yasuhiro ;
Nakamura, Yasuhiro ;
Kawachi, Yasuhiro ;
Otsuka, Fujio .
JOURNAL OF SURGICAL ONCOLOGY, 2012, 106 (01) :41-45
[10]
Sentinel lymph node detection in skin cancer patients using real-time fluorescence navigation with indocyanine green: preliminary experience [J].
Fujiwara, Masao ;
Mizukami, Takahide ;
Suzuki, Ayano ;
Fukamizu, Hidekazu .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2009, 62 (10) :E373-E378