Measuring size distribution in highly heterogeneous systems with fluorescence correlation spectroscopy

被引:177
作者
Sengupta, P [1 ]
Garai, K [1 ]
Balaji, J [1 ]
Periasamy, N [1 ]
Maiti, S [1 ]
机构
[1] Tata Inst Fundamental Res, Dept Chem Sci, Bombay 400005, Maharashtra, India
基金
英国惠康基金;
关键词
D O I
10.1016/S0006-3495(03)75006-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Fluorescence correlation spectroscopy (FCS) is a sensitive and widely used technique for measuring diffusion. FCS data are conventionally modeled with a finite number of diffusing components and fit with a least-square fitting algorithm. This approach is inadequate for analyzing data obtained from highly heterogeneous systems. We introduce a Maximum Entropy Method based fitting routine (MEMFCS) that analyzes FCS data in terms of a quasicontinuous distribution of diffusing components, and also guarantees a maximally wide distribution that is consistent with the data. We verify that for a homogeneous specimen (green fluorescent protein in dilute aqueous solution), both MEMFCS and conventional fitting yield similar results. Further, we incorporate an appropriate goodness of fit criterion in MEMFCS. We show that for errors estimated from a large number of repeated measurements, the reduced X-2 value in MEMFCS analysis does approach unity. We find that the theoretical prediction for errors in FCS experiments overestimates the actual error, but can be empirically modified to serve as a guide for estimating the goodness of the fit where reliable error estimates are unavailable. Finally, we compare the performance of MEMFCS with that of a conventional fitting routine for analyzing simulated data describing a highly heterogeneous distribution containing 41 diffusing species. Both methods fit the data well. However, the conventional fit fails to reproduce the essential features of the input distribution, whereas MEMFCS yields a distribution close to the actual input.
引用
收藏
页码:1977 / 1984
页数:8
相关论文
共 22 条
[1]   2-PHOTON FLUORESCENCE CORRELATION SPECTROSCOPY - METHOD AND APPLICATION TO THE INTRACELLULAR ENVIRONMENT [J].
BERLAND, KM ;
SO, PTC ;
GRATTON, E .
BIOPHYSICAL JOURNAL, 1995, 68 (02) :694-701
[2]   SORTING SINGLE MOLECULES - APPLICATION TO DIAGNOSTICS AND EVOLUTIONARY BIOTECHNOLOGY [J].
EIGEN, M ;
RIGLER, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (13) :5740-5747
[3]   FLUORESCENCE CORRELATION SPECTROSCOPY .1. CONCEPTUAL BASIS AND THEORY [J].
ELSON, EL ;
MAGDE, D .
BIOPOLYMERS, 1974, 13 (01) :1-27
[4]   Dynamics of fluorescence fluctuations in green fluorescent protein observed by fluorescence correlation spectroscopy [J].
Haupts, U ;
Maiti, S ;
Schwille, P ;
Webb, WW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (23) :13573-13578
[5]   STATISTICAL ACCURACY IN FLUORESCENCE CORRELATION SPECTROSCOPY [J].
KOPPEL, DE .
PHYSICAL REVIEW A, 1974, 10 (06) :1938-1945
[6]   ANALYZING THE DISTRIBUTION OF DECAY CONSTANTS IN PULSE-FLUOROMETRY USING THE MAXIMUM-ENTROPY METHOD [J].
LIVESEY, AK ;
BROCHON, JC .
BIOPHYSICAL JOURNAL, 1987, 52 (05) :693-706
[7]   THERMODYNAMIC FLUCTUATIONS IN A REACTING SYSTEM - MEASUREMENT BY FLUORESCENCE CORRELATION SPECTROSCOPY [J].
MAGDE, D ;
WEBB, WW ;
ELSON, E .
PHYSICAL REVIEW LETTERS, 1972, 29 (11) :705-&
[8]   Fluorescence correlation spectroscopy: Diagnostics for sparse molecules [J].
Maiti, S ;
Haupts, U ;
Webb, WW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (22) :11753-11757
[9]   Single-molecule detection by two-photon-excited fluorescence [J].
Mertz, J ;
Xu, C ;
Webb, WW .
OPTICS LETTERS, 1995, 20 (24) :2532-2534
[10]   MAXIMUM-ENTROPY IMAGE-RESTORATION IN ASTRONOMY [J].
NARAYAN, R ;
NITYANANDA, R .
ANNUAL REVIEW OF ASTRONOMY AND ASTROPHYSICS, 1986, 24 :127-170