Improvement of interfacial tension measurement using a captive bubble in conjunction with axisymmetric drop shape analysis (ADSA)

被引:77
作者
Zuo, YY
Ding, M
Bateni, A
Hoorfar, M
Neumann, AW
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] Univ Toronto, Fac Engn & Appl Sci, Div Engn Sci, Toronto, ON M5S 2E4, Canada
关键词
surface tension; axisymmetric drop shape analysis (ADSA); captive bubble; canny edge detector; axisymmetric liquid fluid interfaces-smoothing; (ALFI-S);
D O I
10.1016/j.colsurfa.2004.04.081
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Axisymmetric drop shape analysis (ADSA) is a method to measure surface tension using drop or bubble profiles. Combining ADSA with a captive bubble configuration (ADSA-CB) facilitates pulmonary surfactant related Studies. The accuracy of ADSA-CB is crucially dependent on the quality of the bubble profile extracted from the raw image. In the previous version of ADSA-CB, a global thresholding method was used to segment the bubble profile. However, that technique is of limited accuracy for images with noise and/or lack of contrast. In this paper, a new generation of ADSA-CB using the Canny edge detector was developed. To obtain better results, a novel edge smoothing technique, termed axisymmetric liquid fluid interfaces-smoothing (ALFI-S), was introduced and incorporated with the Canny edge detector to extract bubble profiles. The performance of the new version of ADSA-CB was evaluated using captive bubble images under different conditions. The results suggest that the new methodology is capable of producing accurate surface tension values under a variety of circumstances. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:233 / 246
页数:14
相关论文
共 59 条
[1]  
Adamson S. W., 1990, PHYS CHEM SURFACES
[2]   THE DETERMINATION OF INTERFACIAL-TENSION BY VIDEO IMAGE-PROCESSING OF PENDANT FLUID DROPS [J].
ANASTASIADIS, SH ;
CHEN, JK ;
KOBERSTEIN, JT ;
SIEGEL, AF ;
SOHN, JE ;
EMERSON, JA .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1987, 119 (01) :55-66
[3]  
[Anonymous], 1997, ALGORITHMS IMAGE PRO
[4]   Measurement of surface tension and contact angle using entropic edge detection [J].
Atae-Allah, C ;
Cabrerizo-Vílchez, M ;
Gómez-Lopera, JF ;
Holgado-Terriza, JA ;
Román-Roldán, R ;
Luque-Escamilla, PL .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (03) :288-298
[5]  
Boie R. A., 1986, Proceedings CVPR '86: IEEE Computer Society Conference on Computer Vision and Pattern Recognition (Cat. No.86CH2290-5), P100
[6]  
Boie R. A., 1987, Proceedings of the First International Conference on Computer Vision (Cat. No.87CH2465-3), P450
[7]   Polyethylene glycol (PEG) attenuates exogenous surfactant in lung-injured adult rabbits [J].
Campbell, H ;
Bosma, K ;
Brackenbury, A ;
McCaig, L ;
Yao, LJ ;
Veldhuizen, R ;
Lewis, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (04) :475-480
[9]   COMPUTATIONAL EVALUATION OF AXISYMMETRICAL DROP SHAPE ANALYSIS-PROFILE (ADSA-P) [J].
CHENG, P ;
NEUMANN, AW .
COLLOIDS AND SURFACES, 1992, 62 (04) :297-305
[10]   AUTOMATION OF AXISYMMETRIC DROP SHAPE-ANALYSIS FOR MEASUREMENT OF INTERFACIAL-TENSIONS AND CONTACT ANGLES [J].
CHENG, P ;
LI, D ;
BORUVKA, L ;
ROTENBERG, Y ;
NEUMANN, AW .
COLLOIDS AND SURFACES, 1990, 43 (2-4) :151-167