Novel ibuprofen potentiometric membrane sensors based on tetraphenylporphyrinato indium(III)

被引:31
作者
Hassan, SSM [1 ]
Mahmoud, WH
Elmosallamy, MAF
Almarzooqi, MH
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Zagazig Univ, Fac Sci, Dept Chem, Zagazig, Egypt
关键词
D O I
10.2116/analsci.19.675
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two novel potentiometric membrane sensors responsive to the ibuprofen drug have been developed. These incorporate poly(vinyl chloride) and polyurethane matrix membranes containing 5,10,15,20-tetraphenylporphrinato (TPP) indium(III) ionophore plasticized with dibutylsebacate. The sensors show a near-Nernstian response with anionic slopes of -53 and -55 mV decade(-1), over the concentration range of 4.2 x 10(-6) - 1.0 x 10(-2) and 3.3 x 10(-6) - 1.0 x 10(-2) M ibuprofen within pH ranges of 4 - 9 and 5 - 9 for PVC and PU matrix membranes, respectively. A sensor based on a polyurethane membrane displays a lower detection limit and a wider linear working range, and a sensor based on a PVC membrane exhibits a better overall selectivity, especially in the presence of lipophilic organic anions. Both sensors are used for the quantification and quality-control assessment of ibuprofen in pharmaceutical preparations. The average recoveries are 99.1+/-0.3% and 99.3+/-0.3% for TPP In(Ill)-PVC and TPP In(Ill)-PU based membrane sensors, respectively. High selectivities towards ibuprofen in the presence of many anions, drug excipients and diluents are offered by both sensors, which exhibit a non-Hofmeister selectivity pattern.
引用
收藏
页码:675 / 679
页数:5
相关论文
共 36 条
[1]  
Alder A. D., 1970, J INORG NUCL CHEM, V32, P2443
[2]  
ALY FA, 1994, PHARMAZIE, V49, P454
[3]   ANION SELECTIVITY OF METALLOPORPHYRINS IN MEMBRANES [J].
AMMANN, D ;
HUSER, M ;
KRAUTLER, B ;
RUSTERHOLZ, B ;
SCHULTHESS, P ;
LINDEMANN, B ;
HALDER, E ;
SIMON, W .
HELVETICA CHIMICA ACTA, 1986, 69 (04) :849-854
[4]  
[Anonymous], 1987, Quality Assurance of Chemical Measurements
[5]   Metalloporphyrin-based polymer membrane electrode with high selectivity for 2-hydroxybenzhydroxamate [J].
Badr, IHA ;
Meyerhoff, ME ;
Hassan, SSM .
ANALYTICA CHIMICA ACTA, 1996, 321 (01) :11-19
[6]  
Baeyens W. R. G., 1995, Biomedical Chromatography, V9, P259, DOI 10.1002/bmc.1130090606
[7]  
CHANG Q, 1990, AM BIOTECHNOL LAB, V8, P10
[8]   SALICYLATE-SELECTIVE MEMBRANE-ELECTRODE BASED ON TIN(IV) TETRAPHENYLPORPHYRIN [J].
CHANIOTAKIS, NA ;
PARK, SB ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1989, 61 (06) :566-570
[9]  
CHANIOTAKIS NA, 1988, ANAL CHEM, V60, P188
[10]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544