Comparative electrochemical inactivation of bacteria and bacteriophage

被引:210
作者
Drees, KP
Abbaszadegan, M
Maier, RM
机构
[1] Univ Arizona, Dept Soil Water & Environm Sci, Tucson, AZ 85721 USA
[2] Arizona State Univ, Dept Civil & Environm Engn, Tempe, AZ 85287 USA
关键词
virus; bacteriophage; electrochemical; inactivation; direct; current;
D O I
10.1016/S0043-1354(03)00009-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
Electric fields and currents have been shown to be capable of disinfecting drinking water and reducing the numbers of bacteria and yeast in food. However, little research has been conducted regarding the effectiveness of electric fields and currents in the inactivation of viruses. The objective of this study was to compare the ability of bacteria and bacteriophage to survive exposure to direct electric current in an electrochemical cell, where they would be subject to irreversible membrane permeabilization processes, direct oxidation of cellular/viral constituents by electric current, and disinfection by electrochemically generated oxidants. Suspensions of the bacteria Escherichia coli and Pseudomonas aeruginosa and bacteriophage MS2 and PRD1 at both high (approximately 1 X 10(6) CFU or PFU/mL) and low (approximately 1 X 10(3) CFU or PFU/mL) population densities were exposed to currents ranging from 25 to 3 50 mA in 5s pulses. Post-exposure plaque counts of the bacteriophage were proportionally higher than bacterial culturable counts at corresponding current exposures. E coli and MS2 were then exposed to 5 mA for 20 min at both high and low population densities. The inactivation rate of E coli was 2.1-4.3 times greater than that of MS2. Both bacteria and bacteriophage were more resistant to exposure to direct current at higher population densities. Also, amelioration of inactivation within the electrochemical cell by the reducing agent glutathione indicates the major mechanism of inactivation in the electrochemical cell is disinfection by electrochemically generated oxidants. The implications of these results are that technologies relying upon direct current to reduce the numbers of microbes in food and water may not be sufficient to reduce the numbers of potentially pathogenic viruses and ensure the safety of the treated food or water. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2291 / 2300
页数:10
相关论文
共 18 条
[1]
Protection by extracellular glutathione against sulfur mustard induced toxicity in vitro [J].
Amir, A ;
Chapman, S ;
Gozes, Y ;
Sahar, R ;
Allon, N .
HUMAN & EXPERIMENTAL TOXICOLOGY, 1998, 17 (12) :652-660
[2]
[Anonymous], AM SOC ARTIF INT ORG
[3]
BITTON G, 1994, WASTEWATER MICROBIOL, P87
[4]
CARLEY PJ, 1985, ARCH PHYS MED REHAB, V66, P443
[5]
MECHANISM OF ELECTRICAL ENHANCEMENT OF EFFICACY OF ANTIBIOTICS IN KILLING BIOFILM BACTERIA [J].
COSTERTON, JW ;
ELLIS, B ;
LAM, K ;
JOHNSON, F ;
KHOURY, AE .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1994, 38 (12) :2803-2809
[6]
QUANTIFICATION, QUALIFICATION, AND MICROBIAL KILLING EFFICIENCIES OF ANTIMICROBIAL CHLORINE-BASED SUBSTANCES PRODUCED BY IONTOPHORESIS [J].
DAVIS, CP ;
SHIRTLIFF, ME ;
TRIEFF, NM ;
HOSKINS, SL ;
WARREN, MM .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1994, 38 (12) :2768-2774
[7]
Gaskova D, 1996, BIOELECTROCH BIOENER, V39, P195
[8]
Killing of microorganisms by pulsed electric fields [J].
Grahl, T ;
Markl, H .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1996, 45 (1-2) :148-157
[9]
Mechanisms of the bactericidal activity of low amperage electric current (DC) [J].
Liu, WK ;
Brown, MRW ;
Elliott, TSJ .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1997, 39 (06) :687-695
[10]
DISINFECTION OF DRINKING-WATER BY USING A NOVEL ELECTROCHEMICAL REACTOR EMPLOYING CARBON-CLOTH ELECTRODES [J].
MATSUNAGA, T ;
NAKASONO, S ;
TAKAMUKU, T ;
BURGESS, JG ;
NAKAMURA, N ;
SODE, K .