Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left bundle branch area pacing

被引:317
作者
Vijayaraman, Pugazhendhi [1 ]
Subzposh, Faiz A. [1 ]
Naperkowski, Angela [1 ]
Panikkath, Ragesh [1 ]
John, Kaitlyn [1 ]
Mascarenhas, Vernon [1 ]
Bauch, Terry D. [1 ]
Huang, Weijian [2 ]
机构
[1] Geisinger Commonwealth Sch Med, Geisinger Heart Inst, Wilkes Barre, PA USA
[2] Wenzhou Med Univ, Affiliated Hosp 1, Dept Cardiol, Wenzhou, Peoples R China
关键词
AV block; Conduction system pacing; Echocardiography; His bundle pacing; Left bundle branch area pacing; Physiologic pacing; CARDIAC RESYNCHRONIZATION THERAPY;
D O I
10.1016/j.hrthm.2019.05.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND His bundle pacing (HBP) is the most physiologic form of pacing but associated with higher thresholds and lower success in patients with His-Purkinje conduction disease. Recent reports have described transvenous left bundle branch area pacing (LBBAP). OBJECTIVE We aimed to prospectively evaluate the feasibility and the electrophysiologic and echocardiographic characteristics of LBBAP. METHODS Patients requiring pacing for bradycardia or heart failure indications (failed left ventricular [LV] lead) were prospectively enrolled. LBBAP was performed with a Medtronic 3830 lead. Presence of left bundle branch (LBB) potential, paced QRS morphology/duration, and peak LV activation time (pLVAT) were recorded at implant. Pacing threshold and sensing was assessed at implant and follow-up. Echocardiography was performed to assess the approximate lead location and impact on tricuspid valve function. RESULTS LBBAP was successful in 93 of 100 (93%) patients. Mean age was 75 +/- 13 years; men 69%, left bundle branch block 24%, right bundle branch block 25%, intraventricular conduction defect 8%. Indications for pacing were atrioventricular (AV) block 54%, sinus node dysfunction 23%, AV node ablation 7%, cardiac resynchronization therapy 11%, HBP lead failure 7%. Baseline QRS duration was 133 +/- 35 ms. Paced QRS duration was 136 +/- 17 ms. LBB potentials were observed in 63 patients with left bundle branch - ventricle (LBB-V) interval of 27 +/- 6 ms. pLVAT was 75 +/- 16 ms. Pacing threshold at implant was 0.6 +/- 0.4 V @ 0.5 ms and R waves were 10 +/- 6 mV and remained stable at median follow-up of 3 months. The lead depth in the septum was approximately 1.4 +/- 0.23 cm. CONCLUSIONS LBBAP was feasible in a high percentage of patients with low thresholds during acute follow-up. HBP and LBBAP may significantly increase the overall success of physiologic pacing.
引用
收藏
页码:1774 / 1782
页数:9
相关论文
共 20 条
[1]  
Abdelrahman M, 2018, J AM COLL CARDIOL, V71, P2581, DOI [10.1016/j.jacc.2018.02.048, 10.1016/S0735-1097(18)33122-X]
[2]  
araman P., 2019, J INNOV CARD RHYTHM, V10, P3668
[3]   The Efficacy of His Bundle Pacing: Lessons Learned From Implementation for the First Time at an Experienced Electrophysiology Center [J].
Bhatt, Advay G. ;
Musat, Dan L. ;
Milstein, Nicolle ;
Pimienta, Jacqueline ;
Flynn, Laura ;
Sichrovsky, Tina ;
Preminger, Mark W. ;
Mittal, Suneet .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (11) :1397-1406
[4]   Comparison of electrocardiogram characteristics and pacing parameters between left bundle branch pacing and right ventricular pacing in patients receiving pacemaker therapy [J].
Chen, Keping ;
Li, Yuqiu ;
Dai, Yan ;
Sun, Qi ;
Luo, Bin ;
Li, Chao ;
Zhang, Shu .
EUROPACE, 2019, 21 (04) :673-680
[5]   Long-term outcomes of His bundle pacing in patients with heart failure with left bundle branch block [J].
Huang, Weijian ;
Su, Lan ;
Wu, Shengjie ;
Xu, Lei ;
Xiao, Fangyi ;
Zhou, Xiaohong ;
Mao, Guangyun ;
Vijayaraman, Pugazhendhi ;
Ellenbogen, Kenneth A. .
HEART, 2019, 105 (02) :137-143
[6]   A Novel Pacing Strategy With Low and Stable Output: Pacing the Left Bundle Branch Immediately Beyond the Conduction Block [J].
Huang, Weijian ;
Su, Lan ;
Wu, Shengjie ;
Xu, Lei ;
Xiao, Fangyi ;
Zhou, Xiaohong ;
Ellenbogen, Kenneth A. .
CANADIAN JOURNAL OF CARDIOLOGY, 2017, 33 (12) :1736.e1-1736.e3
[7]  
Kusumoto F M., 2018, Circulation
[8]   His-bundle pacing versus biventricular pacing in cardiac resynchronization therapy patients: A crossover design comparison [J].
Lustgarten, Daniel L. ;
Crespo, Eric M. ;
Arkhipova-Jenkins, Irina ;
Lobel, Robert ;
Winget, Joseph ;
Koehler, Jodi ;
Liberman, Evan ;
Sheldon, Todd .
HEART RHYTHM, 2015, 12 (07) :1548-1557
[9]   Feasibility and Acute Hemodynamic Effect of Left Ventricular Septal Pacing by Transvenous Approach Through the Interventricular Septum [J].
Mafi-Rad, Masih ;
Luermans, Justin G. L. M. ;
Blaauw, Yuri ;
Janssen, Michel ;
Crijns, Harry J. ;
Prinzen, Frits W. ;
Vernooy, Kevin .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (03)
[10]   R-Peak Time: An Electrocardiographic Parameter with Multiple Clinical Applications [J].
Perez-Riera, Andres Ricardo ;
de Abreu, Luiz Carlos ;
Barbosa-Barros, Raimundo ;
Nikus, Kjell C. ;
Baranchuk, Adrian .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2016, 21 (01) :10-19