The effects of three selected Good's pH buffers on the performance of an Fe-0/nitrate/H2O system were evaluated. The Good's pH buffer itself did not reduce nitrate directly. Nitrate reduction by iron powder at near-neutral pH was negligible in an unbuffered system, but it was greatly enhanced with the presence of the buffer. A significant amount of aqueous Fe2+ (or Fe3+) was released after adding the Good's pH buffer into the Fe-0/H2O system with or without nitrate. In general, the pH of the buffered solution increased from the initial pH (= similar to4.6-5.3, depending on buffer's pK(a)) to near-neutral pH. After the initial pH hiking, the pH in the system was more or less stable for a period of time (similar to5-10 h, usually concurrent with a fairly stable aqueous Fe2+). The pH then drifted to similar to7.1 to 8.6, depending on the buffer's initial concentration, the buffer's pK(a) and the consumption of Fe2+ concurrent with nitrate reduction. While a common assumption made by researchers is that Good's pH buffers do not directly participate in reaction processes involved in contaminant remediation, this study shows that as side effects, the Good's pH buffer may react with iron powder.