Non-invasive tissue oximetry for flap monitoring: An initial study

被引:97
作者
Keller, Alex
机构
[1] N Shore Long Isl Jewish Hlth Syst, Div Plast Surg, Dept Surg, New Hyde Pk, NY USA
[2] NYU, Med Ctr, Div Plast Surg, Dept Surg, New York, NY 10016 USA
关键词
noninvasive flap monitoring; near-infrared spectroscopy;
D O I
10.1055/s-2007-974655
中图分类号
R61 [外科手术学];
学科分类号
摘要
The ideal monitoring tool to evaluate free flap success should be noninvasive, continuous, and reliable. A new device, the ViOptix Tissue Oximeter (ODISsey(TM)) based on near-infrared spectroscopy was evaluated in 30 patients undergoing autologous tissue perforator free flap breast reconstruction with continuous monitoring of the flap during elevation, transfer, and the postoperative period. The device accurately reflected the ischemic drop in oxygen saturation during flap transfer, and the hyperemic response after flow was reestablished. There were no flap failures, but in two patients, the device indicated a venous thrombosis before it was clinically obvious and allowed for expeditious flap salvage. The noninvasive nature of the device, the ability to replace and move the probe in the postoperative period, and the measurement of end organ oxygenation are all advantages over other currently available techniques.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 21 条
[1]   Doppler flowmetry in the planning of perforator flaps [J].
Blondeel, PN ;
Beyens, G ;
Verhaeghe, R ;
Van Landuyt, K ;
Tonnard, P ;
Monstrey, SJ ;
Matton, G .
BRITISH JOURNAL OF PLASTIC SURGERY, 1998, 51 (03) :202-209
[2]   FREE FLAP MONITORING USING A MICROCOMPUTER LINKED TO A LASER DOPPLER FLOWMETER [J].
BRUCECHWATT, AJ .
BRITISH JOURNAL OF PLASTIC SURGERY, 1986, 39 (02) :229-238
[3]   SERIAL QUANTITATIVE SKIN SURFACE FLUORESCENCE - A NEW METHOD FOR POSTOPERATIVE MONITORING OF VASCULAR PERFUSION IN REVASCULARIZED DIGITS [J].
GRAHAM, BH ;
GORDON, L ;
ALPERT, BS ;
WALTON, R ;
BUNCKE, HJ ;
LEITNER, DW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1985, 10A (02) :226-230
[4]   Continuous Laser-Doppler free-flap monitoring via the telephone line - Preliminary experiences [J].
Hellekes, D ;
Hettich, R .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1995, 12 (04) :241-244
[5]   Continuous tissue oxygen tension measurement as a monitor of free-flap viability [J].
Hirigoyen, MB ;
Blackwell, KE ;
Zhang, WX ;
Silver, L ;
Weinberg, H ;
Urken, ML .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (03) :763-773
[6]  
Hirigoyen MB, 1995, MICROSURG, V16, P723, DOI 10.1002/micr.1920161103
[7]   DIFFERENTIAL-EFFECTS OF VENOUS STASIS AND ARTERIAL INSUFFICIENCY ON TISSUE OXYGENATION IN MYOCUTANEOUS ISLAND FLAPS - AN EXPERIMENTAL-STUDY IN PIGS [J].
HJORTDAL, VE ;
HAUGE, E ;
HANSEN, ES .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 89 (03) :521-529
[8]   COMPARISON OF LASER-DOPPLER FLOWMETRY AND THERMOMETRY IN THE POSTOPERATIVE MONITORING OF REPLANTATIONS [J].
HOVIUS, SER ;
VANADRICHEM, LNA ;
MULDER, HD ;
VANSTRIK, R ;
VANDERMEULEN, JC .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (01) :88-93
[9]   TISSUE OXIMETRY - AN INTERIM-REPORT [J].
HUNT, TK ;
RABKIN, J ;
JENSEN, JA ;
JONSSON, K ;
VONSMITTEN, K ;
GOODSON, WH .
WORLD JOURNAL OF SURGERY, 1987, 11 (02) :126-132
[10]   EXPERIMENTAL AND CLINICAL MONITORING OF FREE JEJUNAL TRANSFERS USING AN IMPLANTABLE ULTRASONIC DOPPLER PROBE [J].
JONES, NF ;
ROCKE, AM ;
SWARTZ, WM ;
KLEIN, A .
BRITISH JOURNAL OF PLASTIC SURGERY, 1989, 42 (03) :274-280