Examination of mass and modulus contributions to thickness shear mode and surface acoustic wave vapour sensor responses using partition coefficients

被引:46
作者
Grate, JW [1 ]
Kaganove, SN
Bhethanabotla, VR
机构
[1] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
[2] Univ S Florida, Dept Chem Engn, Tampa, FL 33620 USA
关键词
D O I
10.1039/a703601i
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
New data are reported on vapour sorption by four different polymer thin films on thickness shear mode (TSM) and surface acoustic wave (SAW) devices. The polymers examined were poly(isobutylene), PIB, poly(epichlorohydrin), PECH, poly(butadiene), PBD, and poly(dimethylsiloxane), PDMS. The test vapours for the TSM sensor experiments were benzene, toluene, hexane, cyclohexane, chloroform, dichloromethane, carbon tetrachloride and butan-2-one, tested at several concentrations from P/P-0 = ca. 0.03 to 0.64. Measurements on the TSM devices using oscillators were complemented with measurements by impedance analysis. Acoustic wave sensor data were converted to apparent partition coefficients calculated assuming the response was due to mass-loading only. Values derived from SAW and TSM measurements were compared With one another, and with other partition coefficient data determined by non-acoustic wave techniques. It was found that TSM devices coated with PIB, PECH, and PBD (film thickness <1 mu m) behaved as gravimetric sensors at low vapour concentrations. The PDMS-coated TSM sensor displayed significant losses and unusual behaviour suggestive of other effects. SAW sensors with PIB and PECH films gave responses indicating that modulus effects were contributing to the response, in addition to mass-loading effects. This enhancement appeared to be at least a factor of two, suggesting the mass-loading accounted for ca. 50% of the SAW response. The responses of PBD and PDMS-coated SAW devices were not enhanced relative to the expected mass-loading responses. Differences in behaviour among the test polymers on SAW devices are discussed in terms of the differing viscoelastic properties of these materials.
引用
收藏
页码:259 / 283
页数:25
相关论文
共 66 条
  • [2] HYDROGEN-BONDING .19. THE CHARACTERIZATION OF 2 POLY(METHYLPHENYLSILOXANE)S
    ABRAHAM, MH
    WHITING, GS
    ANDONIANHAFTVAN, J
    STEED, JW
    GRATE, JW
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 588 (1-2): : 361 - 364
  • [3] HYDROGEN-BONDING .29. CHARACTERIZATION OF 14 SORBENT COATINGS FOR CHEMICAL MICROSENSORS USING A NEW SOLVATION EQUATION
    ABRAHAM, MH
    ANDONIANHAFTVAN, J
    DU, CM
    DIART, V
    WHITING, GS
    GRATE, JW
    MCGILL, RA
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1995, (02): : 369 - 378
  • [4] STATISTICAL THERMODYNAMICS OF LIQUID-MIXTURES - NEW EXPRESSION FOR EXCESS GIBBS ENERGY OF PARTLY OR COMPLETELY MISCIBLE SYSTEMS
    ABRAMS, DS
    PRAUSNITZ, JM
    [J]. AICHE JOURNAL, 1975, 21 (01) : 116 - 128
  • [5] HIGH POLYMER SOLUTIONS .8. THE VAPOUR PRESSURE OF SOLUTIONS OF POLYISOBUTENE IN TOLUENE AND CYCLOHEXANE
    BAWN, CEH
    PATEL, RD
    [J]. TRANSACTIONS OF THE FARADAY SOCIETY, 1956, 52 (12): : 1664 - 1668
  • [6] Performances of mass-sensitive devices for gas sensing: Thickness shear mode and surface acoustic wave transducers
    Bodenhofer, K
    Hierlemann, A
    Noetzel, G
    Weimar, U
    Gopel, W
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (13) : 2210 - 2218
  • [7] STUDIES IN THE THERMODYNAMICS OF POLYMER-LIQUID SYSTEMS .1. NATURAL RUBBER AND POLAR LIQUIDS
    BOOTH, C
    GEE, G
    HOLDEN, G
    WILLIAMSON, GR
    [J]. POLYMER, 1964, 5 (07) : 343 - 370
  • [8] A 200 MHZ SURFACE ACOUSTIC-WAVE RESONATOR MASS MICROBALANCE
    BOWERS, WD
    CHUAN, RL
    DUONG, TM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (06) : 1624 - 1629
  • [9] MEASUREMENT OF INTERFACIAL PROCESSES AT ELECTRODE SURFACES WITH THE ELECTROCHEMICAL QUARTZ CRYSTAL MICROBALANCE
    BUTTRY, DA
    WARD, MD
    [J]. CHEMICAL REVIEWS, 1992, 92 (06) : 1355 - 1379
  • [10] Conder J.R.C.L. Young., 1979, PHYSICOCHEMICAL MEAS