Seismic performance of precast reinforced and prestressed concrete walls

被引:353
作者
Holden, T
Restrepo, J
Mander, JB
机构
[1] KPFF Consulting Engineers, San Francisco, CA 94111 USA
[2] Univ Calif San Diego, Dept Struct Engn, La Jolla, CA 92093 USA
[3] Univ Canterbury, Christchurch 1, New Zealand
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2003年 / 129卷 / 03期
关键词
seismic stability; walls; concrete; reinforced; precast;
D O I
10.1061/(ASCE)0733-9445(2003)129:3(286)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Two geometrically identical half-scale precast concrete cantilever wall units were constructed and tested under quasi-static reversed cyclic lateral loading. One unit was a code compliant conventionally reinforced specimen, designed to emulate the behavior of a ductile cast-in-place concrete wall. The other unit was part of a precast partially prestressed system that incorporated post-tensioned unbonded carbon fiber tendons and steel fiber reinforced concrete. Hysteretic energy dissipation devices were provided in the latter unit in the form of low yield strength tapered longitudinal reinforcement, acting as a fuse connection between the wall panel and the foundation beam. The conventional precast reinforced wall performed very well in terms of the ductility capacity and energy absorption capability, reaching 2.5% drift before significant strength degradation occurred. The precast partially prestressed wall unit achieved drift levels well in excess of 3% with no visible damage to the wall panel prior to failure. Test results and performance comparisons between the precast partially prestressed wall system and the precast conventionally reinforced unit are presented.
引用
收藏
页码:286 / 296
页数:11
相关论文
共 17 条
  • [1] Cheng, 1997, NCEER970014 STAT U D
  • [2] Chopra A. K, 1995, DYNAMICS STRUCTURES
  • [3] Collins M.P., 1991, Prestressed Concrete Structures
  • [4] CONSTANTIN C, 2001, P 1 C STEEL COMP STR, P1621
  • [5] PERFORMANCE OF BUILDINGS WITH SHEAR WALLS IN EARTHQUAKES OF THE LAST 30 YEARS
    FINTEL, M
    [J]. PCI JOURNAL, 1995, 40 (03): : 62 - 80
  • [6] HOLDEN TJ, 2001, 20014 U CANT DEP CIV
  • [7] Seismic behavior and design of unbonded post-tensioned precast concrete walls
    Kurama, Y
    Pessiki, S
    Sause, R
    Lu, LW
    [J]. PCI JOURNAL, 1999, 44 (03): : 72 - 89
  • [8] Priestley M.J.N., 1993, PCI J, V38, P58
  • [9] Preliminary results and conclusions from the PRESSS five-story precast concrete test building
    Priestley, MJN
    Sritharan, S
    Conley, JR
    Pampanin, S
    [J]. PCI JOURNAL, 1999, 44 (06): : 42 - +
  • [10] RAHMAN A, 2000, 2005 U CANT DEP CIV